Relationship between Abdominal Pressure, Pulmonary Compliance, and Cardiac Preload in a Porcine Model
نویسندگان
چکیده
Rationale. Elevated intra-abdominal pressure (IAP) may compromise respiratory and cardiovascular function by abdomino-thoracic pressure transmission. We aimed (1) to study the effects of elevated IAP on pleural pressure, (2) to understand the implications for lung and chest wall compliances and (3) to determine whether volumetric filling parameters may be more accurate than classical pressure-based filling pressures for preload assessment in the setting of elevated IAP. Methods. In eleven pigs, IAP was increased stepwise from 6 to 30 mmHg. Hemodynamic, esophageal, and pulmonary pressures were recorded. Results. 17% (end-expiratory) to 62% (end-inspiratory) of elevated IAP was transmitted to the thoracic compartment. Respiratory system compliance decreased significantly with elevated IAP and chest wall compliance decreased. Central venous and pulmonary wedge pressure increased with increasing IAP and correlated inversely (r = -0.31) with stroke index (SI). Global end-diastolic volume index was unaffected by IAP and correlated best with SI (r = 0.52). Conclusions. Increased IAP is transferred to the thoracic compartment and results in a decreased respiratory system compliance due to decreased chest wall compliance. Volumetric filling parameters and transmural filling pressures are clearly superior to classical cardiac filling pressures in the assessment of cardiac preload during elevated IAP.
منابع مشابه
Impairment of cardiac performance by laparoscopy in patients receiving positive end-expiratory pressure.
BACKGROUND The cardiopulmonary effects of the combination of abdominal and thoracic pressures in humans have not been well delineated. OBJECTIVE To study the cardiopulmonary effects of 15 mm Hg of intra-abdominal pressure in the presence and absence of 10 cm H20 of positive end-expiratory pressure (PEEP). DESIGN Prospective. SETTING University hospital. METHODS Nine patients undergoing ...
متن کاملAssessment of pulmonary arterial compliance evaluated using harmonic oscillator kinematics
We hypothesized that KPA, a harmonic oscillator kinematics-derived spring constant parameter of the pulmonary artery pressure (PAP) profile, reflects PA compliance in pediatric patients. In this prospective study of 33 children (age range = 0.5-20 years) with various cardiac diseases, we assessed the novel parameter designated as KPA calculated using the pressure phase plane and the equation KP...
متن کامل[Intrathoracic blood volume versus pulmonary artery occlusion pressure as estimators of cardiac preload in critically ill patients].
BACKGROUND Monitoring of cardiac preload by determination of pulmonary artery occlusion pressure (PAOP) has been traditionally used to guide fluid therapy to optimize cardiac output (CO). Since factors such as intrathoracic pressure and ventricular compliance may modify PAOP, volumetric estimators of preload have been developed. The PiCCO system is able to measure CO and intrathoracic blood vol...
متن کاملMechanical Intestinal Obstruction in a Porcine Model: Effects of Intra-Abdominal Hypertension. A Preliminary Study
INTRODUCTION Mechanical intestinal obstruction is a disorder associated with intra-abdominal hypertension and abdominal compartment syndrome. As the large intestine intraluminal and intra-abdominal pressures are increased, so the patient's risk for intestinal ischaemia. Previous studies have focused on hypoperfusion and bacterial translocation without considering the concomitant effect of intra...
متن کاملEndothelin(A)-receptor antagonism attenuates pulmonary hypertension in porcine endotoxin shock.
Porcine endotoxin shock is characterized by pulmonary hypertension, decreased mean arterial pressure and deteriorated cardiac performance. These pathophysiological findings are accompanied by increased plasma endothelin-1 levels. Previous studies have shown that both the pulmonary and systemic circulation are improved by combined endothelinA- and endothelinB-receptor antagonism. This study was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2012 شماره
صفحات -
تاریخ انتشار 2012