Carotid and transcranial color-coded duplex sonography in different types of carotid-cavernous fistula.

نویسندگان

  • Y W Chen
  • J S Jeng
  • H M Liu
  • B S Hwang
  • W H Lin
  • P K Yip
چکیده

BACKGROUND AND PURPOSE Patients with carotid-cavernous fistula (CCF) may undergo direct or indirect shunting. Ultrasonography has value that is complementary to angiography in the assessment and follow-up of these patients. The aim of this study was to characterize findings provided by carotid duplex sonography (CDS) and transcranial color-coded duplex sonography (TCCD) in patients with different types of CCF. METHODS CDS and TCCD were independently performed by technologists and neurologists. Digital subtraction or MR angiography was interpreted by a neuroradiologist. Ultrasonographic studies were categorized into 4 types: I, direct shunting only; II, direct shunting with a carotid aneurysm; III, indirect shunting only; and IV, mixed (direct and indirect) shunting. In addition to carotid and intracranial flow velocities, volume, and pulsatility, other direct and indirect ultrasound signs of shunting were evaluated. The direct sign of CCF was a mosaic flash detected by TCCD. Alteration of hemodynamic parameters on CDS and demonstration of draining veins with the use of TCCD were considered indirect signs. RESULTS Fifteen patients (8 men, 7 women) were included in the study. According to angiographic results, patients in ultrasonographic classification types I (n=7) and II (n=3) corresponded to type A of Barrow's classification. Patients with type III (n=8) were Barrow's type C. Type IV (n=1) had a combination of Barrow's types A and C. On ultrasound, both direct and indirect signs were seen in types I, II, and IV CCF. The presence of a 2-colored oval mass divided by a zone of separation without turbulence differentiated type I from type II CCF. All patients with type III CCF had indirect signs, and only 1 patient had direct signs on TCCD. Abnormal TCCD findings were most commonly seen through the transorbital window (100%), followed by the transtemporal window (63%) and transforaminal window (40%). CONCLUSIONS If only indirect ultrasonographic signs of CCF are present, TCCD can be used to predict an indirect CCF type on the basis of the origin of the fistula. With direct communication between carotid artery and cavernous sinus, both direct and indirect ultrasonographic signs can be found. The combination of CDS/TCCD may provide a noninvasive and reliable way to classify patients with CCF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical relevance of musical murmurs in color-coded carotid and transcranial duplex sonographies.

BACKGROUND AND PURPOSE Musical murmurs (MMs), sometimes called seagull cry, goose cry, honks, or cooing murmur, are murmurs with a single frequency that sounds like a musical tone. Doppler detections usually show mirror-image parallel strings or bands of low to moderate frequency. Musical murmurs are mostly described in cardiac murmurs and have seldom been mentioned in cerebrovascular disease. ...

متن کامل

Transcranial color-coded duplex sonography in unilateral flow-restrictive extracranial carotid artery disease.

PURPOSE To provide transcranial color-coded duplex flow-velocity data for the basal cerebral arteries in patients with unilateral flow-restrictive extracranial carotid artery disease, and to compare these data with the flow velocities obtained in healthy control subjects. METHODS Transcranial color-coded duplex sonography was performed in 78 patients with different patterns of cross flow thro...

متن کامل

Assessment of >/=50% and <50% intracranial stenoses by transcranial color-coded duplex sonography.

BACKGROUND AND PURPOSE A favorable risk-benefit ratio for warfarin compared with aspirin has been reported for the prevention of major vascular events in symptomatic >/=50% intracranial stenoses. Transcranial color-coded duplex sonography (TCCS) criteria providing an accurate detection of >/=50% and <50% stenoses of the anterior, middle, and posterior cerebral arteries and basilar and vertebral...

متن کامل

Contrast-enhanced carotid color-coded duplex sonography for carotid stenting follow-up assessment.

Proper assessment of endovascular patency after carotid stent (CS) placement with carotid color-coded duplex sonography (CCCD) can be difficult. We investigated the usefulness of contrast-enhanced (CE) CCCD for post-CS follow-up. CCCD images could not depict the entire bloodstream in overlapped stents and in highly positioned stents. CE-CCCD images, however, did provide anatomic information alm...

متن کامل

Assessment of intracranial collateral flow by using dynamic arterial spin labeling MRA and transcranial color-coded duplex ultrasound.

BACKGROUND AND PURPOSE To evaluate the potential of a new dynamic MRA sequence (DynAngio) based on arterial spin labeling for the assessment of intracranial collateral flow. METHODS Twelve patients with unilateral internal carotid artery obstruction were investigated. Different patterns of collateral flow were compared between DynAngio, transcranial color-coded duplex ultrasound, and time-of-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 31 3  شماره 

صفحات  -

تاریخ انتشار 2000