Electron microscopy of a muscovitFbiotite interface
ثبت نشده
چکیده
An intergrowth of mucovite and biotite from Mitchell Creek Mine, Upson County, Georgia, was studied with a high resolution transmission electron microscope. Atomic arrangements of the interface between muscovite and biotite have been derived, revealing far more complexity for the interface structure than that proposed previously based on optical and X-ray analysis (Gresens and Stensrud, l97l). It was found that the muscovite has an almost perfectly ordered 2M1 structure, while the biotite is highly disordered. Despite such disorder in biotite, both octahedral layers and K ion interlayers of the two minerals are connected perfectly at the interface, while about ffi% of the tetrahedral sheets are discontinued across the interface. Occasional occurrences of coherent intergrowths of chlorite-like structure in biotite were recognized in the vicinity of the interface.
منابع مشابه
بررسی بارگذاری انفجاری متغیر بر خواص اتصال انفجاری مس به فولاد زنگ نزن مارتنزیتی ۴۱۰
In this research, Effect of explosive ratio parameter on interface properties of explosively bonded copper-410 martensitic stainless steel were investigated, plates were welded in constant standoff distance with different explosive ratios. Optical microscopy, scanning electron microscopy, Microhardness and Tensile shear tests were carried out. The results showed that wavelength, wave amplitude,...
متن کاملبررسی تاثیر مقدار کرنش و دمای نورد بر ریزساختار و سختی اتصال انفجاری ورق های فولاد 304- مس
In this research, the effect of the amount of strain and rolling temperature on the microstructure and the hardness of the explosive bonding of 304 stainless steel- copper sheets was investigated. Explosive welding was performed with two explosive thickness (46 and 79 mm) and stand-off distance (2 and 3 mm). The results of the optical microscope after welding showed that all samples had a commo...
متن کاملبررسی تاثیر فاصله توقف جوشکاری انفجاری بر ساختار و رفتار خوردگی اتصال آلومینیوم 5083- مس در محیط نمک
In the present study, the effect of explosive welding stand-off distance on the structure and corrosion behavior of aluminum alloy 5083-copper joint is studied. The microstructure was examined by optical microscopy and scanning electron microscopy and corrosion behavior with poteniodynamic polarization tests and electrochemical impedance spectroscopy in a salt environment. Microscopic results s...
متن کاملTENSILE AND FRACTURE CHARACTERISTICS OF A SIC- PARTICLE-REINFORCED 7075 ALUMINIUM ALLOY
Fracture behavior of a 7075 aluminium alloy reinforced with 15 Vol%. SiC particles was studied after T6 and annealing heat treatments under uniaxial tensile loading at room temperature. The scanning electron microscopy of fractured surfaces and EDS analysis showed:, that fracture mechanism changed from due mainly to fractured particle in T6 condition to interface decohesion in samples in anneal...
متن کاملInvestigation of Standoff Distance Effect on Corrosion Behavior of Explosively Welded Joint between Two Aluminum Plates and Steel
In the present research, the effect of standoff distance on corrosion properties of the joint of three aluminum–steel explosive layers has been studied. For this purpose, the samples were welded with various standoff distance under constant explosive load. Optical Microscopy and Scanning Electron Microscopy were used to measure the quality of the joint and type of interface. Furthermore, point ...
متن کامل