Evaluation of the Kodak Ektachem DT60 analyser for sodium, potassium, glucose and urea

نویسندگان

  • Gwendolen J. Ayers
  • Caroline Sarah Sherab Rumjen
  • Terence F. Woods
  • David Burnett
چکیده

The Kodak Ektachem DT60/E analyser is a desk-top analyser which uses thin-film ’dry’ chemistry technology to perform colorimetric and potentiometric analyses. The analyser is simple to operate and the slides are claimed to be stablefor up to oneyear if stored at 4 C. Calibration is said to be required only once every three months. Results presented in this paper substantiate these claims and show that the Ektachem DT60/E produces results which are comparable in terms ofbias andprecision with currently used methods for sodium, potassium, urea and glucose. The instrument might have an application within the laboratory for emergency work as well as for out-of-laboratory testing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a novel point-of-care system, the i-STAT portable clinical analyzer.

We evaluated a novel system designed for rapid, point-of-care measurement of sodium, potassium, chloride, urea nitrogen, glucose, and hematocrit. The i-STAT Portable Clinical Analyzer (PCA) system is composed of a hand-held analyzer and disposable cartridges. Sample analysis takes place in the cartridge, which contains a series of thin-film electrodes microfabricated on silicon chips. The PCA w...

متن کامل

Factitiously high sodium activities on the Ektachem 400 owing to interferences by high gamma-globulin concentrations.

Sera from patients with above-normal gamma-globulin concentrations give sodium values as much as 10% higher when measured in the Kodak Ektachem 400 analyzer than results obtained with the Beckman Astra-8 analyzer. Results obtained with the Astra were in agreement with flame photometry. A similar relative bias was observed for potassium measurement in the Ektachem. This discrepancy was corrected...

متن کامل

Evaluation of an engineering model of the "EKTACHEM" analyzer for glucose and urea assay.

We report results of a 21-week evaluation of an engineering model of the Kodak “EKTACHEM Glu/BUN Analyzer.” This novel clinical instrument measures glucose and “urea nitrogen” (actually, urea) in a minimum of 30 j.tL of body fluids by use of the principles of thin, multilayer film analysis and reflectance spectrophotometry. We compared the performance of the instrument to that of the Dupont aca...

متن کامل

Benzalkonium interference with test methods for potassium and sodium.

Six automated instruments that measure sodium and potassium were tested for interference from two compounds used in catheters. Tridodecylmethylammonium heparin did not interfere with any of the methods. However, benzalkonium heparin falsely increased sodium measurement with the Kodak Ektachem, and falsely increased potassium measurements with three instruments (Beckman Astra, Baxter Paramax, an...

متن کامل

Abstracts/Sommaires/Zusammenfassungen

An evaluation of the Kodak glucose/BUN analyzer including experience with proposed testing protocols An evaluation of the analysis of serum urea and plasma_glucose on the Kodak Ektachem GLU/BUN()analyzer is described. It incorporates the experimental design and statistical methods outlined in the Proposed Standard for Establishing Performance Claims (PSEP) (1) for clinical chemical methods PSEP...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 9  شماره 

صفحات  -

تاریخ انتشار 1987