Field evaluation of a passive sampler for assessing 2-ethoxyethyl acetate exposures.

نویسندگان

  • Tung-Sheng Shih
  • Ho-Yuan Chang
  • Hung-Hsin Liu
  • Yi-Shiao Hung
  • Saou-Hsing Liou
چکیده

This paper presents a field evaluation of a passive badge for measuring 2-ethoxyethyl acetate (2-EEAc) in a humid working environment. Forty-eight pairs of side-by-side active/passive 8-h full-shift personal samples were collected to evaluate the performance of a passive badge for monitoring 2-EEAc with the co-exposure of toluene and methyl iso-butyl ketone (MIBK) in a warm and humid workplace. Sixteen pairs of side-by-side passive badges, active charcoal tubes, and active charcoal tube with drying tube samples were also compared to evaluate the humidity effect in sampling. No statistical difference was found between the passive and active samples in assessing 2-EEAc. Linear regression showed the correlation to be high (r=0.987, slope=1.018, n=48) over the range 0.42-41.5 ppm. The mean concentration difference was 0.53 ppm and the mean relative error was 5.39%. Close correlation was also found between passive and active samples for assessing both toluene (r=0.949, slope=0.918, n=16), and MIBK (r=0.943, slope=1.098, n=16). Similar high correlation (r>0.962, n=16) was found among passive badges, active charcoal tubes, and active charcoal tube with drying tube samples. The humidity effect and the interference of co-exposure of polar and non-polar solvents were insignificant at a low sampling rate (26.6 ml/min) in assessing 2-EEAc exposures. The use of the passive samplers produces comparable findings to that of active sampling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A rapidly equilibrating, thin film, passive water sampler for organic contaminants; characterization and field testing.

Improving methods for assessing the spatial and temporal resolution of organic compound concentrations in marine environments is important to the sustainable management of our coastal systems. Here we evaluate the use of ethylene vinyl acetate (EVA) as a candidate polymer for thin-film passive sampling in waters of marine environments. Log K(EVA-W) partition coefficients correlate well (r(2) = ...

متن کامل

Comparison of a passive aerosol sampler to size-selective pump samplers in indoor environments.

The objective of this work was to investigate the ability of the Wagner-Leith passive aerosol sampler to measure indoor exposures over periods of 24 hours to 2 weeks. An automated analysis technique was developed so that lower aerosol concentrations could be sampled over shorter time periods. A test of the new analytical method against a manual method showed good agreement. The passive sampler ...

متن کامل

Evaluating the Relationship between Equilibrium Passive Sampler Uptake and Aquatic Organism Bioaccumulation.

This Critcal Review evaluates passive sampler uptake of hydrophobic organic contaminants (HOCs) in water column and interstitial water exposures as a surrogate for organism bioaccumulation. Fifty-seven studies were found where both passive sampler uptake and organism bioaccumulation were measured and 19 of these investigations provided direct comparisons relating passive sampler uptake and orga...

متن کامل

The creation of pollution mapping and measurement of ambient concentration of sulfur dioxide and nitrogen dioxide with passive sampler

BACKGROUND Measurements of nitrogen and sulfur dioxide using passive sampler over 12 months in Samsun, Turkey, are compared with SO2 and NO2 concentrations obtained from a co-located chemiluminescence analyzer. The concentrations of Sulfur and nitrogen dioxide in the ambient air during the period from November 2009 to September 2010 are analyzed. RESULTS The highest value for annual NO2 and S...

متن کامل

Calibration and field performance of triolein embedded acetate membranes for passive sampling persistent organic pollutants in water.

Triolein embedded cellulose acetate membrane (TECAM) passive samplers provide potentially powerful tool for monitoring time weighted average concentrations (C(TWA)) of trace hydrophobic organic contaminants in water. To study the field performance of TECAM, exchange kinetics of chemicals between water and TECAM were studied at different temperature and water flow rates. Results showed that the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of occupational health

دوره 46 6  شماره 

صفحات  -

تاریخ انتشار 2004