Evaluation of the highly sensitive Roche thyroglobulin II assay and establishment of a reference limit for thyroglobulin-negative patient samples

نویسندگان

  • Dorien M. Rotteveel-de Groot
  • H. Alec Ross
  • Marcel J.R. Janssen
  • Romana T. Netea-Maier
  • Janine D. Oosting
  • Fred C.G.J. Sweep
  • Antonius E. van Herwaarden
چکیده

OBJECTIVES Thyroglobulin (Tg) measurements are used to monitor for residual thyroid tissue in patients with differentiated thyroid cancer (DTC) after thyroidectomy and radioiodine ablative therapy. In recent years highly sensitive Tg assays have been developed. In this study the analytical performance of the new Roche Elecsys Tg II assay was evaluated and compared with the well documented Access2 Tg assay (Beckman-Coulter). DESIGN AND METHODS Analytical performance was examined using various Clinical and Laboratory Standards Institute (CLSI) evaluation protocols. Tg negative patient sera were used to establish an upper reference limit (URL) for the Elecsys Tg II assay. RESULTS Non-linearity, drift and carry-over according to CLSI EP10 and EP6 in a measuring range of 0.04-500 ng/mL were non-significant. Total precision according to CLSI EP5 was 10% at a Tg concentration of 0.08 ng/mL. A patient serum comparison performed according to a modified CLSI EP9 protocol showed a significant difference of a factor of approximately 1.4, despite using an identical CRM calibrator. The Elecsys Tg II assay measured Tg with a two-fold higher sensitivity than the Access2 assay. Finally, using human sera without Tg, an URL of 0.05 ng/mL was determined. CONCLUSIONS In our hands the highly sensitive Elecsys Tg II assay shows a good analytical performance and a higher sensitivity compared to the Access2 Tg assay. An URL of 0.05 ng/mL for the Elecsys Tg II assay was determined which may improve the clinical utility of the assay for the detection of residual DTC or disease recurrence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nonisotopic "sandwich" immunoassay of thyroglobulin in serum by the biotin-streptavidin technique: evaluation and comparison with an immunoradiometric assay.

In this sequential assay, the thyroglobulin in serum binds to polystyrene beads coated with two mouse monoclonal antibodies. These beads then react with a rabbit polyclonal antibody, biotinylated sheep anti-rabbit IgG, streptavidin-horseradish peroxidase, and a peroxidase substrate to yield a colored product that is measured spectrophotometrically at 492 nm. The range of the standard curve is 1...

متن کامل

Serum thyroglobulin antibody levels within or near to the reference range may interfere with thyroglobulin measurement

High concentration of thyroglobulin antibodies (TgAb) is a major limiting factor of thyroglobulin measurements in patients with differentiated thyroid cancer. We investigated whether thyroglobulin antibody added to serum samples could interfere with the thyroglobulin assay. Thyroglobulin levels in serum samples with different concentrations of thyroglobulin were measured by electrochemiluminesc...

متن کامل

Development of a dried whole-blood spot thyroglobulin assay and its evaluation as an indicator of thyroid status in goitrous children receiving iodized salt.

BACKGROUND Serum thyroglobulin appears to be a sensitive marker of thyroid dysfunction in endemic goiter. However, its value as an indicator of thyroid status in children after the introduction of iodized salt has not been tested. OBJECTIVE The objective was to optimize and validate a thyroglobulin assay on dried whole blood spots and to evaluate thyroglobulin as an indicator of thyroid respo...

متن کامل

Development of a dried whole-blood spot thyroglobulin assay and its evaluation as an indicator of thyroid status in goitrous children receiving iodized salt1–3

Background: Serum thyroglobulin appears to be a sensitive marker of thyroid dysfunction in endemic goiter. However, its value as an indicator of thyroid status in children after the introduction of iodized salt has not been tested. Objective: The objective was to optimize and validate a thyroglobulin assay on dried whole blood spots and to evaluate thyroglobulin as an indicator of thyroid respo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016