Stress and strain patterns of 1-piece and 2-piece implant systems in bone: a 3-dimensional finite element analysis.

نویسندگان

  • Zeev Ormianer
  • Arial Ben Amar
  • Mariusz Duda
  • Sharon Marku-Cohen
  • Israel Lewinstein
چکیده

STATEMENT OF PROBLEM The transition from implant to abutment is solid in 1-piece (1P) and broken in 2-piece (2P) implant designs. This difference may affect occlusal load distribution and marginal bone response. PURPOSE To determine whether 1P and 2P implants with equivalent geometries exhibited stresses and strains differently under applied loading conditions. MATERIALS AND METHODS Design software simulated 1P and 2P implants restored with metal copings and embedded in 3 cylindrical bone block models that varied in dimensions, density, and percentage of bone-to-implant contact. Three-dimensional, finite element analysis simulated occlusal loading. Experiments evaluated stresses and strains relative to implant design and (1) periimplant bone thickness, (2) cortical bone thickness, (3) magnitude and direction of occlusal loading, and (4) % bone-to-implant contact. RESULTS Implants with equivalent dimensions exhibited comparable stresses and strains in all experimental conditions. Implant diameter and periimplant bone thickness influenced stress levels. Only small-diameter (3.0 mm) 1P implants in low-density bone exhibited stress levels that might adversely affect marginal bone stability. CONCLUSIONS Implant diameter and periimplant bone thickness influenced load distribution in bone, but the type of implant-abutment transition had no significant effect. Small-diameter 1P implants should be limited to dense bone to minimize stress concentrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تعیین توزیع تنش استخوان اطراف ایمپلنت‌های فک پایین در طرح‎های مختلف پروتز به هنگام Mandibular- Flexure

Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...

متن کامل

Effect of Abutment Angulation and Material on Stress and Strain Distributions in Premaxillary Bone: A Three-Dimensional Finite Element Analysis

Background and Aim: Dental implants with angled abutments are often inserted in the anterior maxillary region due to the status of the residual ridge and aesthetic considerations. The purpose of this study was to assess stress and strain distributions in the premaxillary bone around dental implants by means of finite element analysis (FEA). Materials and Methods: Four three-dimensional (3D) fi...

متن کامل

Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis

Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis Dr. A. Fazel * - Dr. SH. A. Alai ** - Dr. M. Rismanchian *** *Associate Professor of Prosthodontics Dept., Faculty of Dentistry and Dental Research Center, Tehran University / Medical Sciences. **Assistant Professor of Prosthodontics Dept., Faculty of...

متن کامل

Effect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis

Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...

متن کامل

The axisymmetric computational study of a femoral component to analysis the effect of titanium alloy and diameter variation.

This work presents a numerical approach in order to predict the influence of implant material stiffness in a femoral component design when submitted in compression. The implant success depends on the transferred load to the neighboring bone. The finite element method can be used to analysis the stress and strain distribution in the femoral component allowing to improve the implant selection. Fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Implant dentistry

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 2012