Stabilization of autotransplanted teeth using thermoplastic retainers.

نویسندگان

  • Muhammed Isa-Kara
  • Fatih Sari
  • Mehmet Emre-Coşkun
  • Alper Kustarci
  • Hidayet Burak-Polat
  • Hakan Özdemir
  • Serkan Polat
چکیده

OBJECTIVE Different fixation techniques have been used for stabilization of autotransplanted teeth. Because rigid or extended fixation periods can cause complications such as ankylosis and disturbances of pulpal revascularization, our aim was to evaluate an alternative technique, a removable splint, for improving the success rate of autotransplanted molar teeth. STUDY DESIGN In 44 patients, (20 male and 24 female patients), 45 transplanted teeth were analyzed. These cases were followed for 31 to 47 months after operation. Transplanted teeth were evaluated after use of a thermoplastic retainer for 1 month, in terms of success rate and dissatisfaction with this apparatus. The primary stability, ankylosis, and root resorption were also analyzed. RESULTS To date, 1 transplant was extracted after 6 months due to unpreventable periapical root inflammation, and 2 transplants were extracted after one year due to external root resorption. Although 2 ankylosed transplants were still functional after an average follow-up period of three years, with no dissatisfaction by the patients, these cases were treated as failures because of the probable risk for external root resorption. The remaining 40 (88.8 % success rate) transplants remained asymptomatic and functioning for a mean follow-up period of 37 months. In the assessment of dissatisfaction with the thermoplastic retainer, 36 (81.8 %) patients had no or little dissatisfaction, 4 (9 %) patients had very appreciable or excessive dissatisfaction, and 4 (9 %) patients had moderate dissatisfaction. CONCLUSIONS A thermoplastic retainer for use after autotransplantation of third molar teeth is a reasonable and useful method and a good alternative to conventional rigid or semi-rigid splints. This technique was especially useful in autotransplanted teeth that had poor stability, i.e., in cases in which it is conventionally advised to use long-term rigid or semi-rigid splints.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Innovative Approach to Retention: Thermoplastic Retainer.

AIM The aim of this study was to design and introduce a retainer that overcomes the common shortcomings seen in other retainers. MATERIALS AND METHODS Hard thermoplastic sheet of 0.5 mm thickness is vacuum or pressure-molded onto the patient cast. Lingual portion of the retainer is trimmed according to the contours of the anterior teeth. Contact points between the maxillary and mandibular ant...

متن کامل

Effects of thermoplastic retainers on occlusal contacts.

The aim of this prospective study was to evaluate the number of contacts in centric occlusion during retention with thermoplastic retainers (Essix retainers) and in the long term. After four premolar extractions and active orthodontic treatment of 15 Class I (10 females, 5 males; mean age 17.20 +/- 1.7 years), thermoplastic retainers were used. Occlusal contacts were determined from occlusal re...

متن کامل

Analysis of Different Positions of Fiber-Reinforced Composite Retainers versus Multistrand Wire Retainers Using the Finite Element Method

Background. The aim of this study was to evaluate root displacement of the lower incisors fixed with FRC in different positions versus FSW retainers using the finite element method. Materials and Methods. 3D finite element models were designed for a mandibular anterior segment: Model 1: flexible spiral wire bonded to the lingual teeth surfaces, Model 2: FRC bonded to the upper third of lingual ...

متن کامل

An Overview of Fixed and Removable Orthodontic Retainers

 Background and purpose: One of the main challenges in orthodontic treatment is relapse after treatment and return of the teeth to its original position. Therefore, retainers are an essential part of orthodontic treatment. Fixed and removable retainers are commonly used in orthodontic retention. They prevent relapse and require patientchr('39')s cooperation in using them. This review study aime...

متن کامل

Chemical and Mechanical Removal of Staphylococcus Aureus from Orthodontic Retainers

Aim. Recent studies have indicated that non-oral microorganisms are able to colonise intraoral devices such as orthodontic retainers. The aim of this study was to evaluate the effectiveness of chemical and mechanical elimination of Staphylococcus aureus biofilms (MRSA) from thermoplastic discs which were used to represent orthodontic retainers. Methods and Results. Methicillin-resistant Staphyl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medicina oral, patologia oral y cirugia bucal

دوره 16 3  شماره 

صفحات  -

تاریخ انتشار 2011