Validity of MELISA for metal sensitivity testing.

نویسندگان

  • Elizabeth Valentine-Thon
  • Hans-Walter Schiwara
چکیده

OBJECTIVE This study was carried out to evaluate the reproducibility, sensitivity, specificity, and reliability of the MELISA Test for detecting metal sensitivity in patients with clinical symptoms of a type IV hypersensitivity to metal. DESIGN Blood from 250 patients was tested in MELISA against up to 20 different metals in 2 to 3 concentrations. The frequency and distribution of metal reactivities, the sensitivity and specificity of nickel reactivity in patients with and without confirmed or suspected sensitivity to nickel, and the roles of lymphocyte concentration and concentration of inorganic mercury were analyzed. In addition, for reproducibility testing, 196 metal tests were performed in duplicate, and intra- and interassay variations of MELISA results were examined in patients patch-test positive for the relevant metal. RESULTS Among the 250 patients, reactivity to 0, 1, 2, 3, 4, or > or = 5 metals was 26%, 36%, 15%, 12%, 6%, and 5%, respectively. Reactivity was most frequent to nickel (73%), followed by titanium (42%), cadmium (18%) gold (17%), palladium (13%), lead (11%), beryllium (9%), inorganic mercury (8%), tin (8%), and phenylmercury (6%). All patients (n=15) with confirmed or suspected nickel allergy were positive in MELISA, while patients with no suspicion of nickel allergy were either negative (n=6) or very low positive (n=4) in MELISA. MELISA reactivity is directly dependent on lymphocyte concentration: the higher the lymphocyte concentration per test, the stronger the reactivity. Concentrations of inorganic mercury > 0.5 microg/ml cause non antigen-specific (mitogenic) reactions in a majority of patients. The reproducibility rate was 94% using a cut-off of Stimulation Index > or = 3 or 99% using a cut-off of > or = 5. While the absolute intra- and interassay Stimulation Index values may vary, the qualitative results are highly reproducible. CONCLUSION The MELISA Test is reproducible, sensitive, specific, and reliable for detecting metal sensitivity in metal-sensitive patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

LTT-MELISA is clinically relevant for detecting and monitoring metal sensitivity.

OBJECTIVES Chronic low-level metal exposure may result in metal sensitization and undesirable side-effects. The main sources of metal exposure are from the environment or from corrosion of dental metal alloys. Affected patients are routinely diagnosed with the epicutaneous (patch) test. However, such testing may induce false-positive (irritative) reactions and may in itself sensitize or exacerb...

متن کامل

Metal-specific lymphocyte reactivity is downregulated after dental metal replacement.

OBJECTIVES This study was done to evaluate the results and clinical relevance of an optimized lymphocyte proliferation test, MELISA, for metal-induced inflammation in patients with CFS-like symptoms. The treatment of patients consisted of the replacement of incompatible dental materials (RID) together with supportive anti-oxidant therapy. DESIGN OF THE STUDY 513 patients were tested by MELISA...

متن کامل

Identifying and diagnosing patients with metal hypersensitivity MELISA® TESTING IN ORTHOPAEDICS

Patients suffering from metal hypersensitivity may have local symptoms associated with an overactive immune response such as localised pain, swelling, cutaneous allergic reactions, joint and muscle pain, implant failure or recurrent suspected infections around the operation site. Also, systemic reactions such as fibromyalgia and chronic fatigue can be exacerbated or triggered by metal hypersens...

متن کامل

MELISA-an in vitro tool for the study of metal allergy.

The sensitizing properties of metals widely used in medical and dental care have been studied with the help of an optimized lymphocyte proliferative assay, MELISA. MELISA (memory lymphocyte immuno-stimulation assay) was originally developed for the screening of allergenic epitopes of drugs and other chemicals of low molecular weight, but has recently been adapted for the study of metal-induced ...

متن کامل

Metal-specific lymphocytes: biomarkers of sensitivity in man.

Many patients attribute their health problems to amalgam and other dental metals. In genetically susceptible indviduals, mercury and gold may function as haptens and elicit allergic and autoimmune reactions. The frequency of metal-induced lymphocyte responses was examined in 3,162 patients in three European laboratories using MELISA(R), an optimized lymphocyte proliferation test. The patients s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neuro endocrinology letters

دوره 24 1-2  شماره 

صفحات  -

تاریخ انتشار 2003