Direct endocardial recording from an accessory atrioventricular pathway: localization of the site of block, effect of antiarrhythmic drugs, and attempt at nonsurgical ablation.
نویسندگان
چکیده
We recorded a discrete 0.95 mV potential consistent with accessory atrioventricular pathway (AP) activation during serial electrophysiologic studies in a patient with Ebstein's anomaly and Wolff-Parkinson-White syndrome. Bipolar pacing from the catheter electrode in which the AP potential was recorded resulted in a stimulus-ventricle interval identical to the AP-ventricle interval during antegrade conduction, and a stimulus-atrium interval identical to the AP-atrium interval during retrograde conduction. With the patient in the drug-free state, antegrade AP block during atrial pacing and retrograde AP block during ventricular pacing occurred distal to the AP potential (AP-ventricle junction and AP-atrium junction, respectively), supporting the "impedance mismatch" hypothesis. Procainamide and disopyramide each lengthened the antegrade AP effective refractory period by affecting the AP-ventricle junction (possibly by decreasing the current generated by the AP). Both drugs also lengthened the retrograde AP effective refractory period but produced a greater effect on the ventricle-AP junction than on the AP-atrium junction, suggesting marginal geometry of the former. R wave synchronous shocks of 160 and 320 W-sec delivered between the catheter electrode recording the largest unipolar AP potential and a skin electrode produced transient, complete, antegrade block over the AP, suggesting the feasibility of this new nonsurgical technique for AP ablation.
منابع مشابه
Accessory atrioventricular pathways refractory to catheter ablation: role of percutaneous epicardial approach.
BACKGROUND Epicardial mapping and ablation of accessory pathways through a subxiphoid approach can be an alternative when endocardial or epicardial transvenous mapping has failed. METHODS AND RESULTS We reviewed acute and long-term follow-up of 21 patients (14 males) referred for percutaneous epicardial accessory pathway ablation. There was a median of 2 previous failed procedures. All patien...
متن کاملCatheter ablation of accessory pathways with a direct approach. Results in 35 patients.
Thirty-five consecutive patients with an overt accessory pathway, all but two suffering from arrhythmia (atrial fibrillation, reciprocating tachycardia, or both), underwent attempted transcatheter ablation (fulguration) of their accessory pathway. Thirty-three patients had been treated with a mean of 2.3 +/- 1.4 antiarrhythmic drugs. A standard bipolar catheter was positioned on the internal su...
متن کاملHigh frequency alternating current ablation of an accessory pathway in humans.
High frequency alternating current ablation of an accessory pathway was performed in a patient with incessant circus movement tachycardia using a right-sided, free wall accessory pathway. Antiarrhythmic drugs, antitachycardia pacing and transvenous catheter ablation using high energy direct current shocks could not control the supraventricular tachycardia. A 7F bipolar electrode catheter with a...
متن کاملRadiofrequency endocardial catheter ablation of accessory atrioventricular pathway atrial insertion sites.
BACKGROUND High rates of success using radiofrequency ablation energy have rapidly transformed catheter ablation from an investigational procedure to the nonpharmacological therapy of choice for symptomatic Wolff-Parkinson-White syndrome. Prior studies of radiofrequency accessory pathway ablation were based on a ventricular approach. Risks associated with prolonged arterial catheter manipulatio...
متن کاملFrequency-dependent electrophysiological properties of concealed slow pathway of isolated rabbit atrioventricular node preparation after fast pathway ablation in a functional model
Introduction: Intranodal pathways of atrioventricular (AV) node play a vital role in the delay of conduction time in response to various atrial inputs. The present study was aimed to determine the frequency-dependent electrophysiological properties of concealed slow pathway according to a functional model of isolated rabbit atrioventricular node preparation after fast pathway ablation. Meth...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 68 5 شماره
صفحات -
تاریخ انتشار 1983