Transgenically produced human antithrombin: structural and functional comparison to human plasma-derived antithrombin.

نویسندگان

  • T Edmunds
  • S M Van Patten
  • J Pollock
  • E Hanson
  • R Bernasconi
  • E Higgins
  • P Manavalan
  • C Ziomek
  • H Meade
  • J M McPherson
  • E S Cole
چکیده

Recombinant human antithrombin (rhAT) produced in transgenic goat milk was purified to greater than 99%. The specific activity of the rhAT was identical to human plasma-derived AT (phAT) in an in vitro thrombin inhibition assay. However, rhAT had a fourfold higher affinity for heparin than phAT. The rhAT was analyzed and compared with phAT by reverse phase high-performance liquid chromatography, circular dichroism, fluorophore-assisted carbohydrate electrophoresis (FACE), amino acid sequence, and liquid chromatography/mass spectrography peptide mapping. Based on these analyses, rhAT was determined to be structurally identical to phAT except for differences in glycosylation. Oligomannose structures were found on the Asn 155 site of the transgenic protein, whereas only complex structures were observed on the plasma protein. RhAT contained a GalNAc for galactose substitution on some N-linked oligosaccharides, as well as a high degree of fucosylation. RhAT was less sialylated than phAT and contained both N-acetylneuraminic and N-glycolylneuraminic acid. We postulate that the increase in affinity for heparin found with rhAT resulted from the presence of oligomannose-type structures on the Asn 155 glycosylation site and differences in sialylation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of recombinant human antithrombin III synthesized in Chinese hamster ovary cells.

Biochemical and physiochemical properties of recombinant human antithrombin III were examined. This protein, produced in Chinese hamster ovary cells, showed a conformation apparently identical with the natural product isolated from human plasma when examined by circular dichroism, UV absorbance, and fluorescence spectroscopy. Comparison of the NH2-terminal sequences of recombinant and human pla...

متن کامل

Monoclonal antibodies against plasma protease inhibitors: production and characterization of 15 monoclonal antibodies against human antithrombin III. Relation between antigenic determinants and functional sites of antithrombin III.

Fifteen hybridomas secreting monoclonal antibodies against human antithrombin III, originating from two mouse strains, have been produced by the cell fusion technique. Eight monoclonal antibodies belong to the class IgG1, five to the class IgG2a, and two to the class IgG2b. All light chains belong to the kappa group. No cross-reaction of the monoclonal antibodies have been observed with a crude...

متن کامل

Antithrombin III Utilization in a Large Teaching Hospital.

In a retrospective study to assess the use of antithrombin concentrates, the authors judged the plasma-derived product (Thrombate III) to be more cost-effective than the recombinant human form (ATryn) for patients with hereditary antithrombin deficiency.

متن کامل

Heparin cofactor activities in a family with hereditary antithrombin III deficiency: evidence for a second heparin cofactor in human plasma.

Plasma levels of antithrombin-heparin cofactor, determined by heparin-dependent antithrombin assay, and antithrombin III antigen were measured in 22 members of a large kindred predisposed to venous thrombosis. While 11 members had reduced plasma levels of both antithrombin-heparin cofactor and antithrombin III antigen, the levels of antithrombin-heparin cofactor were always greater than the lev...

متن کامل

The rabbit as an animal model for the activated factor X-antithrombin III-heparin reaction.

When activated factor X (Xa) inhibitory activity of serially diluted human and rabbit plasma is determined in a low salt assay, a lineare plot is obtained for human, but not for rabbit plasma. When a high salt assay is used, the dilution curves for both human and rabbit plasma are linear, and qualititive as well as quantitative differences are essentially eliminated. On Sephadex G-200 chromatog...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Blood

دوره 91 12  شماره 

صفحات  -

تاریخ انتشار 1998