Comparison of transverse wires and half pins in Taylor Spatial Frame: A biomechanical study
نویسندگان
چکیده
BACKGROUND The aim of this study was to compare the stiffness characteristics of Taylor Spatial Frame (TSF) fixed with transverse wires and half pins. DESIGN & METHODS Experiments were carried out at the biomechanics laboratory at Cardiff University. All mechanical testing was performed with a servo hydraulic test frame (MTS 858 Mini Bionix II(R), MTS Corp., Mineapolis, USA). Custom built mounts were used to attach the bone rigidly to the one end of machine and the TSF ring to the other. Rings were fixed with 1.8 mm transverse wires or hydroxy-apatite coated 6.5 mm half pins in 45 degrees, 60 degrees, 75 degrees and 90 degrees divergence angles. Bone was loaded with axial load to 400 N and torque to 20 Nm in an indestructible manner. Load/displacement curve data were analyzed for slope and axial and angular displacements. RESULTS For larger diameter rings (180 mm), for axial stiffness there was no statistically significant difference between the transverse wires (4 wires with 2 rings) and the half pins (2 pins with 1 ring) (p > 0.05). For 155 mm internal diameter rings, half pins provided statistically higher axial stiffness than transverse wires (p = 0.036). The half pins show significantly more torsion stiffness in both ring diameters (p < 0.05) in comparison to transverse wires. As in axial stiffness, small diameter rings show increased stiffness in torsion. There is increase in axial and torsion stiffness with the increase in the divergence angle between the wires or pins (p < 0.05). CONCLUSION & CLINICAL RELEVANCE Half pins provide greater stiffness to TSF frames and allow for axial micro motion as well. This work provides a rationale for clinical decision making about the use of tensioned transverse wires in comparison to half pins in construction of a TSF frame.
منابع مشابه
Techniques for improving stability in oblique fractures treated by circular fixation with particular reference to the sagittal plane.
Biomechanical studies involving all-wire and hybrid types of circular frame have shown that oblique tibial fractures remain unstable when they are loaded. We have assessed a range of techniques for enhancing the fixation of these fractures. Eight models were constructed using Sawbones tibiae and standard Sheffield ring fixators, to which six additional fixation techniques were applied sequentia...
متن کاملThe influence of a weight-bearing platform on the mechanical behavior of two Ilizarov ring fixators: tensioned wires vs. half-pins
BACKGROUND A weight-bearing platform applied at the distal end of an Ilizarov external frame allows patients with hindfoot transfixations, foot deformities or plantar skin lesions to bear weight. This leads to an indirect loading of the fracture or osteotomy site. However, the effect on the fracture/osteotomy site's motion or compressive loads is unknown. The aim of this study was to analyze th...
متن کاملImproved wire stiffness with modified connection bolts in Ilizarov external frames: a biomechanical study.
Frame stability in Ilizarov external fixators is mainly dependent on the tension of the transosseous wires, which are clamped to the ring by connection bolts. It was the purpose of this biomechanical study to investigate the holding capacity of a modified bolt design featuring a ruffled wire-bolt interface (TrueLok™) and its influence on wire stiffness in comparison with that of classic bolts f...
متن کاملStability at the half pin–frame interface on external fixation constructs
A mechanical study investigating the use of two different methods (grub and bolt screws) to secure external fixation half pins to circular frames. A four part experiment: (1) Grub and bolt screws were used to secure half pins in Taylor Spatial frames. Loosening torques were measured using a calibrated torque wrench. (2) Using universal testing machine (UTM), axial loading was applied to establi...
متن کاملIn vitro biomechanical comparison of three methods for internal fixation of femoral neck fractures in dogs.
The in vitro biomechanical properties of three methods for internal fixation of femoral neck fractures were evaluated. Fifty cadaveric femura from Beagle dogs were used. Ten intact femora served as controls. In 40 femura, an osteotomy of the femoral neck was performed to simulate a transverse fracture. With the remaining 30 femura, three repair methods (two medium Orthofix pins, a 2.7 mm cort...
متن کامل