Doppler evaluation of peripheral vascular adaptations to transverse aortic banding in mice.

نویسندگان

  • Yi-Heng Li
  • Anilkumar K Reddy
  • George E Taffet
  • Lloyd H Michael
  • Mark L Entman
  • Craig J Hartley
چکیده

Transverse aortic banding in mice is commonly used to produce pressure overload, but the resulting cardiac hypertrophy is variable and the actual load produced is unknown. The purposes of the study were to characterize peripheral blood flow in banded mice using noninvasive Doppler methods, investigate whether changes in flow could predict the amount of cardiac hypertrophy induced and validate the simplified Bernoulli equation for estimating the pressure drop across the stenosis in very small vessels. Wild-type mice underwent aortic banding (n=15) or sham operation (n=6). Doppler velocity was measured in the right and left carotid arteries (RCA and LCA) 1 day later, and the heart weight/body weight ratio was measured at 7 days. The RCA/LCA peak velocity ratio at 1 day was significantly correlated with the heart weight/body weight ratio at 7 days after banding (r=0.62, p<0.005). In another 12 banded mice, serial Doppler velocity signals were obtained from the aortic banding site, the abdominal aorta (ABD) and the RCA and LCA before, 1 day after and 7 days after banding. Peak RCA velocity increased significantly after banding and both peak LCA velocity and peak ABD velocity decreased significantly. Mean velocities of RCA, LCA and ABD were unchanged before and after banding, suggesting that mice utilize peripheral arterial adaptations to maintain normal cerebral and peripheral perfusion. There was a significant positive correlation (r=0.83, p<0.001) between the RCA/LCA peak velocity ratio and peak jet velocity across the aortic banding site. Our data indicate that changes in carotid velocity after aortic banding can be used to estimate the pressure drop across the aortic band and to predict loading and resulting cardiac hypertrophy in mice. Additionally, we validated that the simplified Bernoulli equation (DeltaP=4V2) can be used to estimate the pressure drop across the aortic band in mice noninvasively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Doppler velocity measurements from large and small arteries of mice.

With the growth of genetic engineering, mice have become increasingly common as models of human diseases, and this has stimulated the development of techniques to assess the murine cardiovascular system. Our group has developed nonimaging and dedicated Doppler techniques for measuring blood velocity in the large and small peripheral arteries of anesthetized mice. We translated technology origin...

متن کامل

Decompensation of Pressure-Overload Hypertrophy in Gaq-Overexpressing Mice

Background—Receptor-mediated activation of myocardial Gq signaling is postulated as a biochemical mechanism transducing pressure-overload hypertrophy. The specific effects of Gq activation on the functional and morphological adaptations to pressure overload are not known. Methods and Results—To determine the effects of intrinsic myocyte Gaq signaling on the left ventricular hypertrophic respons...

متن کامل

Minimally invasive aortic banding in mice: Effects of altered cardiomyocyte insulin signaling during pressure-overload Running Title: Minimally invasive aortic banding and insulin signaling

We have developed a minimally invasive method for producing left ventricular pressure-overload in mice. Using this technique we quickly and reproducibly banded the transverse aorta with low surgical morbidity and mortality. Minimally invasive transverse aortic banding (MTAB) acutely and chronically increased left ventricular (LV) systolic pressure, increased heart weight/body weight and induced...

متن کامل

Endothelial Vasodilator Angiotensin Receptors are Changing in Mice with Ageing

Background: The vascular function of Angiotensin II-type-2 receptors in adults is controversial. We sought their location and function in mouse aortic rings at young and old mice. Materials and Methods: Male C57Bl mice (aged 4 and 14 months) were killed by CO2. The descending thoracic aorta was cleaned and dissected into rings. Aortic rings were mounted in Krebs&rsquo; solution at 37 &deg;C an...

متن کامل

Left ventricular hypertrophy induced by reduced aortic compliance.

AIM It was the aim of this study to investigate the long- term effects of reduced aortic compliance on cardiovascular hemodynamics and cardiac remodeling. METHOD Sixteen swine, divided into 2 groups, a control and a banding group, were instrumented for pressure and flow measurement in the ascending aorta. Teflon prosthesis was wrapped around the aortic arch in order to limit wall compliance i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasound in medicine & biology

دوره 29 9  شماره 

صفحات  -

تاریخ انتشار 2003