In vivo photoacoustic tomography of myoglobin oxygen saturation.

نویسندگان

  • Li Lin
  • Junjie Yao
  • Lei Li
  • Lihong V Wang
چکیده

Myoglobin is an essential oxygen-binding hemoprotein in skeletal and cardiac muscles that buffers intracellular oxygen (O2) concentration in response to hypoxia or elevated muscle activities. We present a method that uses photoacoustic computed tomography to measure the distribution of myoglobin in tissue and the oxygen saturation of myoglobin (sO2-Mb ). From photoacoustic measurements of mice in different oxygenation states, we performed calibration-free quantification of the sO2-Mb change in the backbone muscle in vivo.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photoacoustic imaging of real-time oxygen changes in chronic leg ulcers after topical application of a haemoglobin spray: a pilot study.

OBJECTIVE To use a non-invasive measurement of oxygen saturation in chronic leg ulcers after the application of a topical haemoglobin spray to investigate if photoacoustic tomography is able to measure the oxygen saturation and if the stimulated oxygen increase can be demonstrated. METHOD We measured the oxygen saturation of the ulcer tissue in five patients with chronic leg ulcers before app...

متن کامل

Calibration-free quantification of absolute oxygen saturation based on the dynamics of photoacoustic signals.

Photoacoustic tomography (PAT) is a hybrid imaging technique that has broad preclinical and clinical applications. Based on the photoacoustic effect, PAT directly measures specific optical absorption, which is the product of the tissue-intrinsic optical absorption coefficient and the local optical fluence. Therefore, quantitative PAT, such as absolute oxygen saturation (sO₂) quantification, req...

متن کامل

Photoacoustic tomography of small animal brain with a curved array transducer.

We present the application of a curved array photoacoustic tomographic imaging system that can provide rapid, high-resolution photoacoustic imaging of small animal brains. The system is optimized to produce a B-mode, 90-deg field-of-view image at sub-200-microm resolution at a frame rate of approximately 1 frame/second when a 10-Hz pulse repetition rate laser is employed. By rotating samples, a...

متن کامل

Photoacoustic computed microscopy

Photoacoustic microscopy (PAM) is emerging as a powerful technique for imaging microvasculature at depths beyond the ~1 mm depth limit associated with confocal microscopy, two-photon microscopy and optical coherence tomography. PAM, however, is currently qualitative in nature and cannot quantitatively measure important functional parameters including oxyhemoglobin (HbO2), deoxyhemoglobin (HbR),...

متن کامل

hotoacoustic tomography of small animal brain with a urved array transducer

ihong V. Wang ashington University in St. Louis epartment of Biomedical Engineering ptical Imaging Laboratory t. Louis, Missouri 63130 Abstract. We present the application of a curved array photoacoustic tomographic imaging system that can provide rapid, high-resolution photoacoustic imaging of small animal brains. The system is optimized to produce a B-mode, 90-deg field-of-view image at sub-2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 21 6  شماره 

صفحات  -

تاریخ انتشار 2016