Forgotten electrical accidents and the birth of shockproof X-ray systems
نویسندگان
چکیده
OBJECTIVES To commemorate victims of electrical accidents that occurred in the first decades of radiology and relate these accidents to the evolution of the X-ray apparatus. METHODS Digitised newspapers, scientific journals, books and reports of legal procedures were searched for electrical accidents involving X-ray systems. Information on the historical systems was retrieved from the scientific literature and brochures from manufacturers. RESULTS We found 51 fatal and 62 non-fatal but serious electrical accidents. Most of them occurred between 1920 and 1940 and involved transformers that provided output currents well above the threshold for the induction of ventricular fibrillation. The accidents led to recommendations and regulations to improve safety for operators and patients, and spurred manufacturers to technical developments that culminated in fully electrically shockproof systems by 1935. CONCLUSIONS Although largely forgotten, the development of the shockproof X-ray systems we take for granted today lasted about 4 decades and was associated with considerable human suffering. The complete solution of the problem is a success story of engineering realised by contributions from all parties involved. MAIN MESSAGES • The development of electrically shockproof X-ray systems took about 4 decades (1895-1935). • Between 1896 and 1920 electrical shocks from X-ray systems were common, but their consequences limited. • After 1920, transformers killed by delivering currents above the ventricular fibrillation threshold. • Inductors, static generators and high-frequency coils were generally low-current systems and safe. • We found 51 fatal and 62 serious non-fatal electrical accidents, most occurring from 1920 to 1940.
منابع مشابه
Forty Years of X-Ray Binaries
In 2012 it was forty years ago that the discovery of the first X-ray binary Centaurus X-3 became known. That same year it was discovered that apart from the High-Mass X-ray Binaries (HMXBs) there are also Low-Mass X-ray Binaries (LMXBs), and that Cygnus X-1 is most probably a black hole. By 1975 also the new class of Be/X-ray binaries was discovered. After this it took 28 years before ESAs INTE...
متن کاملDesign and Simulation of Hot Cathode Ionization Vacuum Gauge with no X-Ray Limitations
In this paper, the MEMS type ionization gauge with no X-Ray limitations has been presented. Having the dimensions of 2.4 mm× 0.8mm × 1.4 mm, the designed gauge is 9000 times smaller than the conventional type and can operate in HV and UHV pressures up to 5×10-9 torr. Operating at the temperature of 750°C, the cathode of proposed gauge is implemented using nickel and works in a way in...
متن کاملOptimum driving a Z-pinch for soft X-Ray lasers
A capillary plasma z-pinch as an alternative active medium of soft X-Ray lasers was studied experimentally and theoretically. The theoretical analysis was based on the self consistent solution of the so called “snow plow” model. The dynamics of pinched plasma is determined by the capillary parameters and by the time dependence of electrical current passing through it. The current time dependenc...
متن کاملanalysis of Parameter related to electrocution accidents based on evaluation of electrical safety performance in small-scale industries
Introduction: Electrocutions have a low frequency and severe consequences. The purpose of this study was to analyze the parameters related to electrical accidents, and evaluation of electrical safety performance of small-scale industries. Method: This study was conducted in 2019 on 232 small-scale industries. Electrical accidents over a 7-year period were studied. The tools used included elect...
متن کاملOptimization of Non-volatile Memory Cell and Energy Consumption in Robot Systems by Synthesized Silicon Nanoparticles via Electrical Discharge
In this paper, we propose to optimize manufacturing methods of memory cells by produced silicon nanoparticles via electrical spark discharge of silicon electrodes in water to reduce the energy consumption for low power applications. The pulsed spark discharge with the peak current of 60 A and a duration of a single discharge pulse of 60 µs was used in our experiment. The structure, morphology, ...
متن کامل