Biomechanical Measurement Error Can Be Caused by Fujifilm Thickness: A Theoretical, Experimental, and Computational Analysis

نویسندگان

  • Ahmed Sarwar
  • Simli Srivastava
  • Chris Chu
  • Alan Machin
  • Emil H Schemitsch
  • Habiba Bougherara
  • Zahra S Bagheri
  • Radovan Zdero
چکیده

This is the first study to quantify the measurement error due to the physical thickness of Fujifilm for several material combinations relevant to orthopaedics. Theoretical and experimental analyses were conducted for cylinder-on-flat indentation over a series of forces (750 and 3000 N), cylinder diameters (0 to 80 mm), and material combinations (metal-on-metal, MOM; metal-on-polymer, MOP; metal-on-bone, MOB). For the scenario without Fujifilm, classic Hertzian theory predicted the true line-type contact width as WO = {(8FDcyl)/(πLcyl)[(1 - νcyl2)/Ecyl + (1 - νflat2)/Eflat]}1/2, where F is compressive force, Dcyl is cylinder diameter, Lcyl is cylinder length, νcyl and νflat are cylinder and flat Poisson's ratios, and Ecyl and Eflat are cylinder and flat elastic moduli. For the scenario with Fujifilm, experimental measurements resulted in contact widths of WF = 0.1778 × F0.2273 × D0.2936 for MOM tests, WF = 0.0449 × F0.4664 × D0.4201 for MOP tests, and WF = 0.1647 × F0.2397 × D0.3394 for MOB tests, where F is compressive force and D is cylinder diameter. Fujifilm thickness error ratio WF /WO showed a nonlinear decrease versus cylinder diameter, whilst error graphs shifted down as force increased. Computational finite element analysis for several test cases agreed with theoretical and experimental data, respectively, to within 3.3% and 1.4%. Despite its wide use, Fujifilm's measurement errors must be kept in mind when employed in orthopaedic biomechanics research.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical analysis of blast-induced traumatic brain injury

  Purpose: Blast-induced traumatic brain injury (bTBI) is one of the causes of death or permanent   invalidity which can occur unexpectedly in both military and civilian populations. This study   set out to conduct a combined Eulerian-Lagrangian computational analysis of the interaction   between a single planar blast wave and a human head in order to assess the extent of intracranial   shock w...

متن کامل

Effect of Oral Administration of Silymarin on Healing Full-thickness Gastric Wound in Rats

Background and Objectives: Gastrotomy can be accompanied by serious postoperative complications. In this regard, the present study aimed to evaluate the effects of oral administration of silymarin on the histopathological and biomechanical characteristics of the gastric wall after experimental gastrotomy in rats.   Methods: Full-thickness incision on the gastric wall and then suturing were con...

متن کامل

Histopathological and Biomechanical Study on the Effect of Aftemisia sieberi Extract on Experimental Skin Wound llealing in Rat

Objectiv e- To eval uate the effects of Artemisia sieberi extract on experimental dermal wounds healing .Design- Experimental study.Animals- 30 male Spragne-Dawly rats.Procedures- Two uniform 7 mm diameter skin defect were created on the back of each animal by skinpunch (total of 60 wounds). Then, the extract of the plant was applied once daily on half of the wounds forhistopathological and bio...

متن کامل

THEORETICAL AND EXPERIMENTAL EVALUATION OF DISLOCATION DENSITY IN A WORKPIECE AFTER FORMING

Abstract: The theoretical calculation of dislocation density in different regions of a deformed workpiece of 99.99% pure copper has been carried out using different procedures consisting of Finite Element Method (FEM) and hardness measurement. To assess the validity of the results pertaining to these procedures, the dislocation density is experimentally measured utilizing the Differential...

متن کامل

An Experimental and Theoretical Investigation of Corrosion Mechanism in a Metallic Stack

This paper presents an experimental and theoretical investigation of the causes of corrosion of stack in a cement plant. In this paper, information related to metallic stack failures are given in the form of a case study in Neka Cement Plant, Mazandaran, Iran. Heavy corrosion attacks were observed on the samples of stack. The failure can be caused by one or more modes such as overheating, stres...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017