The effect of injectable biocompatible elastomer (PDMS) on the strength of the proximal fixation of EVAR-grafts An in-vitro study

ثبت نشده
چکیده

Purpose: One of the major concerns in the long-term success of EVAR is stent-graft migration, which can cause type I endoleak and even aneurysm rupture. Fixation depends on the mechanical forces between the graft and both the aortic neck and the blood flow. Therefore there are anatomical restrictions for EVAR, such as short and angulated necks. To improve the fixation of EVAR-grafts, elastomer (PDMS) can be injected in the aneurysm sac. The support given by the elastomer might prevent dislocation and migration of the graft. The aim of this study was to measure the influence of an injectable biocompatible elastomer on the fixation strength of different EVAR-grafts in an in-vitro model. methods: The proximal part of 3 different stent grafts was inserted in a bovine artery with an attached latex aneurysm. The graft was connected to a tensile testing machine, applying force to the proximal fixation, while the artery with the aneurysm was fixated to the set-up. The force to obtain graft dislodgement (DF) from the aorta was recorded in Newtons (N). Three different proximal seal lengths (5, 10 and 15 mm) were evaluated. The experiments were repeated after the space between the graft and the latex aneurysm was filled with the elastomer. Independent sample T-tests were used for the comparison between the DF before and after elastomer treatment for each seal length. results: The mean DF (mean ±SD) of all grafts without elastomer sac filling for a proximal seal length of 5, 10 and 15 mm were respectively, 4.4±3.1N, 12.2±10.6N and 15.1±6.9N. After elastomer sac-filling the dislodgement forces increased significantly (p<0.001) to: 20.9±3.8N, 31.8±9.8N and 36.0±14.1N. conclusions: The present study shows that aneurysm sac filling may have a role as an adjuvant procedure to the present EVAR technique. The strength of the proximal fixation of three different stent-grafts increases significantly in this in-vitro setting. Further in-vivo research must be done to see if this could facilitate the treatment of aneurysms with short infrarenal necks. Effect of Sac-filling on Proximal Fixation 93

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Elastomer Additive Improving Elastic Properties of Heavy Weight Oil Well Cement: A Laboratory Study

The use of elastomer additives to solve the problems in oil well cementing has been investigated in recent years by several research groups in the petroleum industry. This study includes the laboratory examination of the effect of elastomer additives on the physical properties of heavy-weight oil well cement. In the research process, a candidate well is selected and the properties of the cement...

متن کامل

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

An investigation on injectable composites fabricated by 45S5 bioactive glass and gum tragacanth: Rheological properties and in vitro behavior

The injectable composites were formulated from melt-derived 45S5 bioactive glass powder and gum tragacanth. The effect of tragacanth concentration (2 and 4 w/v%) and powder to liquid ratio (P/L= 1.5 to 2.5) on rheological properties, injectability, degradation, swelling, and bioactivity the composites was studied. With the increase of P/L ratio and tragacanth concentration, the force requ...

متن کامل

Nanocomposite flexible pressure sensor for biomedical applications

A new approach for the fabrication of flexible pressure sensors based on aligned carbon nanotubes (A-CNTs) is described in this paper. The technology is suitable for blood pressure sensors that can be attached to a stent-graft and deployed during an endovascular aneurysm repair (EVAR) procedure. Given the specifications of EVAR, the device should be foldable (extremely flexible) and characteriz...

متن کامل

Autogenous Osteochondral Transplantation Mosaicplasty (An Animal Study on Sheep)

Background: Autogenous osteochondral grafting of articular defect in weight-bearing surface of large joints has proven to be a proper biomechanical and physiological solution for localized full-thickness defects.Objective: To study the gross and histopathological results of mosaicplasty in an animal model (sheep’s medial femoral condyle), evaluating the factors of defect and graft size, assessi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011