The Joint International Symposium on EPR Dosimetry and Dating and the International Conference on Biological Dosimetry (EPR-BioDose 2013).

نویسنده

  • Firouz Darroudi
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrospective dosimetry using fingernail in nuclear industries: A review paper

Generally, doses greater than 2Gy can produce acute biological effects in humans. For this reason, to measure and record the cumulative dose, especially in radiation users, the need for a personal dosimeter has been strongly felt by the researchers. The purpose of this study is to introduce retrospective dosimetric techniques, in particular the use of nails as a natural tool for determining cum...

متن کامل

EPR Dosimetry of Chernobyl Liquidators

The paper is devoted to review of development and application of EPR dosimetry with teeth in Ukraine. It deals with specific features of the EPR dosimetry protocol, which was developed and is practically used in SCRM for retrospective dosimetry of clean-up workers (liquidators). Extensive methodological research was conducted in SCRM in order to develop an original version of EPR dosimetric pro...

متن کامل

Overview of physical dosimetry methods for triage application integrated in the new European network RENEB.

PURPOSE In the EC-funded project RENEB (Realizing the European Network in Biodosimetry), physical methods applied to fortuitous dosimetric materials are used to complement biological dosimetry, to increase dose assessment capacity for large-scale radiation/nuclear accidents. This paper describes the work performed to implement Optically Stimulated Luminescence (OSL) and Electron Paramagnetic Re...

متن کامل

ساخت دزیمتر EPR نانوبلور استرانسیوم سولفات آلاییده با دیسپرسیوم و بررسی خواص دزیمتری آن

The dosimetric characteristics of γ-radiation induced defects in strontium sulfate rod dosimeter were investigated using electron paramagnetic resonance (EPR) technique focusing on the dose range of 10–15000 Gy. The most significant EPR signals of spectroscopic splitting factor (g-value) g=2.0036 ، g=2.0090 and g=2.0160 were observed and attributed respectively to the SO4¯, SO3&...

متن کامل

The 4th international comparison on EPR dosimetry with tooth enamel Part 1: Report on the results

This paper presents the results of the 4th International Comparison of in vitro electron paramagnetic resonance dosimetry with tooth enamel, where the performance parameters of tooth enamel dosimetry methods were compared among sixteen laboratories from all over the world. The participating laboratories were asked to determine a calibration curve with a set of tooth enamel powder samples provid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 159 1-4  شماره 

صفحات  -

تاریخ انتشار 2014