Within-Breath Analysis of Respiratory Mechanics in Asthmatic Patients by Forced Oscillation

نویسندگان

  • Juliana Veiga
  • Agnaldo José Lopes
  • José Manoel Jansen
  • Pedro Lopes de Melo
چکیده

INTRODUCTION The within-breath analysis of respiratory mechanics by the monofrequency Forced Oscillation Technique (mFOT) is of great interest in both physiopathology studies and the diagnosis of respiratory diseases. However, there are limited data on the use of this technique in the analysis of asthma. This study evaluates within-breath mechanics of asthmatic individuals and the contribution of the mFOT in the asthma diagnosis. METHODS Twenty-two healthy and twenty-two asthmatic subjects, including patients with mild (n=8), moderate (n=8), and severe (n=6) obstruction, were studied. Forced Oscillation Technique data were interpreted using the mean respiratory impedance (Zt), the impedance during inspiration (Zi), expiration (Ze), at the beginning of inspiration (Zii), and at expiration (Zie). The peak-to-peak impedance (Zpp) was also calculated by the subtraction of Zii from Zie. Receiver operating characteristic curves were used to determine the sensitivity (Se) and specificity (Sp) of m Forced Oscillation Technique parameters in identifying asthma. RESULTS Respiratory impedance values were significantly higher in asthmatics: Zt (p<0.001), Zi (p<0.001), Ze (p<0.001), Zii (p<0.001), Zie (p<0.001), and Zpp (p<0.003). The best parameters for detecting asthma were Zi, Zii, and Zie (Se=90.9%, Sp=90.9%), followed by Zt and Ze. These results are in close agreement with recently published theories and pathophysiological fundamentals. CONCLUSIONS mFOT permits a non-invasive and detailed analysis in different phases of the respiratory cycle, providing parameters that are adequate for the diagnosis of asthma with high accuracy. These results confirm the high clinical and scientific potential of this methodology in the evaluation of asthmatic patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Within-breath respiratory impedance and airway obstruction in patients with chronic obstructive pulmonary disease

OBJECTIVE Recent work has suggested that within-breath respiratory impedance measurements performed using the forced oscillation technique may help to noninvasively evaluate respiratory mechanics. We investigated the influence of airway obstruction on the within-breath forced oscillation technique in smokers and chronic obstructive pulmonary disease patients and evaluated the contribution of th...

متن کامل

Usefulness of Colored 3D Imaging of Respiratory Impedance in Asthma

PURPOSE Recently, the clinical application of the forced oscillation technique (FOT) has progressed with the spread of commercially available FOT devices, including the impulse oscillation system and MostGraph. We investigated the usefulness of color 3D imaging of respiratory impedance in asthma using MostGraph. METHODS Whole-breath and within-breath respiratory system resistance (Rrs) and re...

متن کامل

Adenosine level in exhaled breath increases during exercise-induced bronchoconstriction.

In asthmatic patients, airway obstruction provoked by exercise challenge is accompanied by an increase in plasma adenosine level. In this study, the current authors investigated if exercise-induced bronchoconstriction was associated with local changes of adenosine concentration in the airways. Oral exhaled breath condensate (EBC) collection (5-min duration) and forced expiratory volume in one s...

متن کامل

Servocontrolled generator to measure respiratory impedance from 0.25 to 26 Hz in ventilated patients at different PEEP levels.

Assessing respiratory impedance (Zrs) in ventilated patients over a wide frequency band, ranging from breathing rates to typical forced oscillation frequencies, during end-expiratory pauses at different positive end-expiratory pressures (PEEP) is of potential interest to assess a patient's respiratory mechanics. Zrs measurements under these conditions are not possible with the present variants ...

متن کامل

بررسی غلظت روی سرم و تأثیر مکمل یاری با روی بر عملکرد تنفسی بیماران بتلا به آسم

    Background and Aim: Asthma, as the most prevalent disorder of the airways is accompanied with excessive inflammatory, oxidative and apoptotic activity. In asthmatic patients, serum and hair levels of zinc are decreased. Zinc, as an essential micronutrient for human is reported to have anti inflammatory, anti oxidant and anti apoptosis roles. This study was conducted to investigate the effec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 64  شماره 

صفحات  -

تاریخ انتشار 2009