Survival of uncemented acetabular monoblock cups

نویسندگان

  • Rüdiger J Weiss
  • Nils P Hailer
  • André Stark
  • Johan Kärrholm
چکیده

BACKGROUND AND PURPOSE Monoblock acetabular cups represent a subtype of uncemented cups with the polyethylene liner molded into a metal shell, thus eliminating-or at least minimizing-potential backside wear. We hypothesized that the use of monoblock cups could reduce the incidence of osteolysis and aseptic loosening, and thus improve survival compared to modular designs. PATIENTS AND METHODS We identified all 210 primary total hip arthroplasty (THA) procedures in the Swedish Hip Arthroplasty Register that used uncemented monoblock cups during the period 1999-2010. Kaplan-Meier and Cox regression analyses with adjustment for age, sex, and other variables were used to calculate survival rates and adjusted hazard ratios (HRs) of the revision risk for any reason. 1,130 modular cups, inserted during the same time period, were used as a control group. RESULTS There was a nearly equal sex distribution in both groups. Median age at the index operation was 47 years in the monoblock group and 56 years in the control group (p < 0.001). The cumulative 5-year survival with any revision as the endpoint was 95% (95% CI: 91-98) for monoblock cups and 97% (CI: 96-98) for modular cups (p = 0.6). The adjusted HR for revision of monoblock cups compared to modular cups was 2 (CI: 0.8-6; p = 0.1). The use of 28-mm prosthesis heads rather than 22-mm heads reduced the risk of cup revision (HR = 0.2, CI: 0.1-0.5; p = 0.001). INTERPRETATION Both cups showed good medium-term survival rates. There was no statistically significant difference in revision risk between the cup designs. Further review of the current patient population is warranted to determine the long-term durability and risk of revision of monoblock cup designs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical and radiological outcome following total hip arthroplasty with an uncemented trabecular metal monoblock acetabular cup.

Uncemented acetabular components are associated with a significant incidence of polyethylene wear and secondary osteolysis. The new tantalum/polyethylene composite (Hedrocel) acetabular component is designed to reduce the polyethylene wear and to increase the longevity of the acetabular cups. We report our short- term clinical outcome and patient satisfaction following use of an uncemented tant...

متن کامل

A cemented cup with acetabular impaction bone grafting is more cost-effective than an uncemented cup in patients under 50 years.

PURPOSE Acetabular deficiencies in young patients can be restored in several ways during total hip arthroplasty. Currently, cementless cups are most frequently used. Impaction bone grafting of acetabular defects is a more biological approach, but is it cost-effective in young patients on the long term? METHODS We designed a decision model for a cost-utility analysis of a cemented cup with ace...

متن کامل

Hedrocel trabecular metal monoblock acetabular cups: mid-term results.

The most important factors for long-term survival of cementless prostheses are the initial fixation, the osteoconducting properties of the metal shell and the bony response. Porous tantalum, a new biomaterial with a geometric structure similar to trabecular bone, was reported in animal studies to allow for bone ingrowth even when 3-mm gaps exist between the implant and the bone. This new materi...

متن کامل

Deformation of Press-Fit Metal Acetabular Components following Impaction into Physiologically Relevant Models

INTRODUCTION For a stable uncemented acetabular shell or monoblock cup post implantation, the acetabula cavity is reamed to a smaller diameter (up to 4 mm) than that of the component, resulting in an interference fit [1]. Press-fit cups and shells have a range of porous coatings on their outer surface to promote bone ingrowth which support long-term stability. A number of previous FE and experi...

متن کامل

Cemented Polyethylene Cups in Patients Younger Than 40 Years

UNLABELLED Although uncemented cup implants frequently are used in young patients, we believe long-term survival rates of cups in these patients are somewhat disappointing, and therefore we have continued to use cemented cups in primary THA, even in young patients. However, in cases of acetabular bone stock defects, we also use bone impaction grafting. We prospectively followed 130 patients wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 83  شماره 

صفحات  -

تاریخ انتشار 2012