Systematic errors in isothermal titration calorimetry: concentrations and baselines.
نویسندگان
چکیده
In the study of 1:1 binding by isothermal titration calorimetry, reagent concentration errors are fully absorbed in the data analysis, giving incorrect values for the key parameters--K, ΔH, and n--with no effect on the least-squares statistics. Reanalysis of results from an interlaboratory study of a selected biochemical process demonstrates that concentration errors are likely responsible for most of the overall statistical error in these parameters. The concentration errors are approximately 10%, greatly exceeding expected levels. Furthermore, examination of selected data sets reveals a surprising sensitivity to the baseline, suggesting a need for great care in treating dilution heats.
منابع مشابه
Biological Applications of Isothermal Titration Calorimetry
Most of the biological phenomena are influenced by intermolecular recognition and interaction. Thus, understanding the thermodynamics of biomacromolecule ligand interaction is a very interesting area in biochemistry and biotechnology. One of the most powerful techniques to obtain precise information about the energetics of (bio) molecules binding to other biological macromolecules is isoth...
متن کاملMetal ions binding study on human growth hormone by isothermal titration calorimetric method
The interaction of hGH with some metal ions ( ) at 27°C in NaC1 solution, 50 mM was studied using Isothermal titration calorimetry. There is a set of three identical and non-interacting binding sites for binding of all these metal ions, expect . The intrinsic association equilibrium constants () are not very different for and , and also their molar enthalpies of binding (KJ/mol for and KJ/mo...
متن کاملTitration Calorimetry Standards and the Precision of Isothermal Titration Calorimetry Data
Current Isothermal Titration Calorimetry (ITC) data in the literature have relatively high errors in the measured enthalpies of protein-ligand binding reactions. There is a need for universal validation standards for titration calorimeters. Several inorganic salt co-precipitation and buffer protonation reactions have been suggested as possible enthalpy standards. The performances of several com...
متن کاملIsothermal Titration Calorimetry and Molecular Dynamics Simulation Studies on the Binding of Indometacin with Human Serum Albumin
Human serum albumin (HSA) is the most abundant protein in the blood plasma. Drug binding to HSA is crucial to study the absorption, distribution, metabolism, efficiency and bioavailability of drug molecules. In this study, isothermal titration calorimetry and molecular dynamics simulation of HSA and its complex with indometacin (IM) were performed to investigate thermodynamics parameters and th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical biochemistry
دوره 414 2 شماره
صفحات -
تاریخ انتشار 2011