Anion-exchange chromatographic determination of bromide in serum.

نویسندگان

  • M E Miller
  • C J Cappon
چکیده

In this liquid-chromatographic method for the determination of bromide in human serum, an important and unique feature is pre-analysis ultrafiltration of the sample, which effectively removes proteins. The chromatographic system consists of an anion-exchange column (Whatman Partisil SAX 10-micron particles), an isocratic phosphate-buffered mobile phase, and ultraviolet detection at 195 nm. The absolute detection limit, 0.6 ng of bromide, makes this method the most sensitive assay for serum bromide yet reported. The day-to-day CV ranged from 1.6% to 4.9%. Analytical recovery of bromide added to serum samples ranged from 96.2% to 108.8%. Data on bromide in serum are presented for adults and newborns and for adults given bromide orally.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Preconcentration and Determination of Pb2+, Cu2+, Co2+, Ni2+, Fe2+ and Zn2+ Elements in Water Samples Using Citrate Form of Anion-Exchange Resin

Lead, copper, cobalt, nickel, iron and zinc ions form monocitrate complexes (negative charge) in citrate solution which is absorbed on the citrate form of anion-exchange resins (citrate as counter ion) y exchange of citrate ion with citrate complexes. These are subsequently recovered from the resin by 0.5M ammonium citrate eluent at pH 2.0. Under optimized conditions, quantitative recovery ...

متن کامل

Chromatography of Serum Proteins in Normal and Pathologic Sera: the Distribution of Protein-bound Carbohydrate

Chromatographic techniques have recently been introduced which provide new approaches to serum protein separation and characterization (1-4). Sober, Gutter, Wyckoff, and Peterson, using diethylaminoethyl (DEAE) cellulose, described the initial application of anion-exchange cellulose chromatography to the fractionation and identification of serum proteins (1, 2). Their study indicated the great ...

متن کامل

Determination of anions at trace levels in power plant water samples by ion chromatography with electrolytic eluent generation and suppression.

An ion chromatographic method was developed for the determination of nine inorganic and organic acid anions at sub- to low-microg/l levels in power plant water samples. In this method, samples were injected using a large-volume direct injection technique, the analyte anions were separated on a hydroxide-selective anion-exchange column using high-purity hydroxide eluents generated by an on-line ...

متن کامل

Kinetic study of the concentration dependence of the mass transfer rate coefficient in anion-exchange chromatography of bovine serum albumin.

The experimental results of a previous study of the mass transfer kinetics of bovine serum albumin (BSA) in ion-exchange chromatography under nonlinear conditions are reevaluated. The analysis of the concentration dependence of the lumped mass-transfer rate coefficient (k(m,L)) provides information on the kinetics of axial dispersion, fluid-to-particle mass transfer, intraparticle mass transfer...

متن کامل

Onboard determination of submicromolar nitrate in seawater by anion-exchange chromatography with lithium chloride eluent.

Ion-exchange chromatography using a high-capacity anion exchanger with UV detection was applied to the determination of nitrate in seawater. Major ions in seawater samples did not affect the peak shape and the retention time of the nitrate when an alkaline metal cation-chloride solution was used as an eluent at high concentrations (0.5-2 mol/l). At a wavelength of 220 nm, the peak of bromide wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 30 5  شماره 

صفحات  -

تاریخ انتشار 1984