Biomechanical comparison of a locking compression plate combined with an intramedullary pin or a polyetheretherketone rod in a cadaveric canine tibia gap model.
نویسندگان
چکیده
OBJECTIVE To compare the biomechanical properties of a 10-hole 3.5 mm locking compression plate (LCP) with 2 proximal and 2 distal bicortical locked screws reinforced with either a Steinmann pin of 30-40% the medullary diameter or a poly-ether-ether-ketone (PEEK) rod of ∼75% the medullary diameter in a cadaveric tibia gap model. STUDY DESIGN Ex vivo study. SAMPLE POPULATION Cadaveric canine tibias (n = 8 pair). METHODS Each construct had a 10-hole 3.5 mm LCP with 2 screws per fracture fragment using a comminuted tibia gap model. The Steinmann pin constructs had a 2.4 mm intramedullary pin whereas the PEEK-rod constructs had a 6 mm intramedullary PEEK rod placed. Biomechanical testing included non-destructive bi-planar 4 point bending, torsion testing, and destructive axial compression. Testing produced the responses of failure load (N) in axial compression, stiffness (N/mm or N/°) in axial compression, torsion, lateral-medial, and caudal-cranial 4 point bending. Screw position within the PEEK-rods was determined after explantation. RESULTS The PEEK-rod constructs were significantly stiffer in axial compression (P < .005), lateral-medial 4 point bending (P < .001), and in torsional loading (P < .031) than the Steinman pin constructs. There was no significant difference between the constructs for stiffness in caudal-cranial 4 point bending (P = .32). The PEEK-rod constructs failed at a significantly higher load than the Steinmann pin constructs (P < .001). All constructs failed by yielding through plastic deformation. Each screw penetrated the PEEK rod in all constructs but the position of the screw varied. CONCLUSION PEEK-rod constructs failed at significantly higher loads and were significantly stiffer in 4 point lateral-medial bending, axial compression, and torsion when compared with Steinmann pin constructs.
منابع مشابه
The use of combined 3.5 LCP unicortical plate and nail fixation in proximal tibia fractures and prevention of valgus and anterior angulation
Introduction: Intramedullary nailing (IMN) of high tibia fracture has some mechanical and biological advantages over the other form of fixation. However, valgus, apex anterior malalignment and anterior displacement of proximal fragment commonly occur after isolated IMN fixation of proximal high tibia fracture. The purpose of this study is to determine the effectiveness of using 3.5-mm locking c...
متن کاملA biomechanical comparison study of a modern fibular nail and distal fibular locking plate in AO/OTA 44C2 ankle fractures
BACKGROUND A lateral approach with open reduction and internal fixation with a plate is a very effective technique for the majority of distal fibular fractures. However, this open approach for ankle fixation may be complicated by wound dehiscence and infection, especially in high-risk patients. An alternative to plating is an intramedullary implant, which allows maintenance of length, alignment...
متن کاملA Biomechanical Comparison of a Novel Expandable Photodynamic Intramedullary System to a Metal Plate and Screw System in Humerus and Femur Osteotomy Models
The biomechanical performance of a locking compression plate system was compared to an intramedullary photodynamic bone stabilization system in a femur and humerus osteotomy model. The photodynamic bone stabilization system utilizes an angioplasty-like balloon that is introduced into the intramedullary canal of a fractured bone, filled with monomer that is then polymerized and hardened by visib...
متن کاملA biomechanical comparison of conventional dynamic compression plates and string-of-pearls™ locking plates using cantilever bending in a canine Ilial fracture model
BACKGROUND Fracture of the ilium is common orthopedic injury that often requires surgical stabilization in canine patients. Of the various methods of surgical stabilization available, application of a lateral bone plate to the ilium is the most common method of fixation. Many plating options are available, each having its own advantages and disadvantages. The purpose of this study was to evalua...
متن کاملBiomechanical Analysis of Operative Methods in the Treatment of Extra-Articular Fracture of the Proximal Tibia
BACKGROUND To determine relative fixation strengths of a single lateral locking plate, a double construct of a locking plate, and a tibial nail used in treatment of proximal tibial extra-articular fractures. METHODS Three groups of composite tibial synthetic bones consisting of 5 specimens per group were included: lateral plating (LP) using a locking compression plate-proximal lateral tibia (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Veterinary surgery : VS
دوره 43 8 شماره
صفحات -
تاریخ انتشار 2014