Two Methods for Analysis of Dynamic Scintigraphic Images of the Heart
نویسندگان
چکیده
Dynamic scintigraphic images allow functional exploration of the considered organ and thus a good comprehension of the pathological phenomenon. There are two different approaches to analyse such images series; by following the activity of a region of interest or by computing parametric images. Both approaches may require the detection of an area of interest. This paper presents two methods of analysis of synchronised dynamic scintigraphic images of the heart based on an automatic detection of the left ventricle. The first method follows the time activity of the left ventricle and computes the ventricular ejection fraction. The second method computes a parametric image called “covariance image” where each pixel represents a covariance coefficient that indicates if the corresponding point in the heart and the reference area evolve or not in the same direction. The results of the application of the two methods on several dynamic images are presented and discussed.
منابع مشابه
Estimating Tumor/Non-Tumor Uptake from Radiolabeled Monoclonal Antibodies using Scintigraphic Images and Dissecting the Animal Models
Introduction: Biodistribution study in animal models bearing tumors is one of the most important procedures in evaluation of fractional uptake of radiopharmaceuticals in the tumor and non-tumor organs. The aim of this study was to develop a new software-based method to determine activities that accumulate in the main organs as well as the tumor based on scintigraphy images, thereby obviating th...
متن کاملEnergy window setting for optimum Tl-201 cardiac imaging [Persian]
Introduction: Poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. Scattered photons are the main cause of degrading the contrast and resolution in SPECT imaging that result in error in quantification. Thallium decay is ve...
متن کاملScintigraphic evaluation of abomasal emptying rate in neonatal suckling lambs
Evaluation of gastric emptying rate using nuclear scintigraphy as the gold standard method has been studied in various animals, but there is no report in suckling lambs. The aim of this study was to develop a nuclear scintigraphic method to visualize and measure abomasal emptying rate by estimation of scintigraphic half emptying time (T1/2) in the live neonatal lamb. Five healthy, female Irania...
متن کاملSegmentation of the Left Atrial Appendage in the Echocardiographic Images of the Heart Using a Deep Neural Network
Introduction: Cardiovascular diseases are one of the leading causes of mortality in today’s industrial world. Occlusion of left atrial appendage (LAA) using the manufactured devices is a growing trend. The objective of this study was to develop a computer-aided diagnosis system for the identification of LAA in echocardiographic images. Method: The data used in this descriptive analytical study ...
متن کاملSegmentation of the Left Atrial Appendage in the Echocardiographic Images of the Heart Using a Deep Neural Network
Introduction: Cardiovascular diseases are one of the leading causes of mortality in today’s industrial world. Occlusion of left atrial appendage (LAA) using the manufactured devices is a growing trend. The objective of this study was to develop a computer-aided diagnosis system for the identification of LAA in echocardiographic images. Method: The data used in this descriptive analytical study ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Int. Arab J. Inf. Technol.
دوره 3 شماره
صفحات -
تاریخ انتشار 2006