Increased risk of revision of acetabular cups coated with hydroxyapatite
نویسندگان
چکیده
BACKGROUND Hydroxyapatite (HA) is the main inorganic component of bone, and HA coating is widely used on acetabular cups in hip arthroplasty. It has been suggested that this surface finish improves cup survival. METHODS All patients registered in the Swedish Hip Arthroplasty Register between 1992 and 2007 with an uncemented acetabular implant that was available either with or without HA coating were identified. 8,043 total hip arthroplasties (THAs) with the most common cup types (Harris-Galante, Romanus, and Trilogy) were investigated. A Cox regression model including type of coating, age, sex, primary diagnosis, cup type, and type of stem fixation was used to calculate adjusted risk ratios (RRs) for the risk of revision. RESULTS HA coating was a risk factor for cup revision due to aseptic loosening (adjusted RR 1.7; 95% CI: 1.3-2). Age at primary arthroplasty of < 50 years, a diagnosis of pediatric hip disease, the use of a cemented stem, and the Romanus and Harris-Galante cup types were also associated with statistically significantly increased risk of cup revision due to aseptic loosening. INTERPRETATION Our findings question the routine use of HA-coated cups in primary total hip arthroplasty. With some designs, this practice may even increase the risk of loosening-resulting in revision surgery.
منابع مشابه
The performance of two hydroxyapatite-coated acetabular cups compared with Charnley cups. From the Norwegian Arthroplasty Register.
We have compared the survival of two hydroxyapatite (HA)-coated cups, 1208 Atoll hemispheric and 2641 Tropic threaded, with cemented Charnley all-polyethylene cups (16 021) using the Cox regression model. The Tropic cup used in combination with an alumina ceramic femoral head, had good results, similar to those of the Charnley cup. When used in combination with a stainless-steel head, however, ...
متن کاملInfluence of cementless cup surface on stability and bone fixation 2 years after total hip arthroplasty.
Loss of fixation between bone and implant surface is one of the main treatment problems in total hip arthroplasty. It might lead to implant instability, bone loss and treatment failure resulting in revision surgery. Surface modification is a method for improving bone response to implant and increasing implant osseointegration. However, the currently applied modifications such as hydroxyapatite ...
متن کاملFailure of dual radius hydroxyapatite-coated acetabular cups
INTRODUCTION Many kind of hydroxyapatite-coated cups were used, with favorable results in short term studies; it was supposed that its use could improve osteointegration of the cup, enhancing thus stability and survivorship. The purpose of this study is to analyze the long term behavior of the hemispheric HA coated, Dual Radius Osteonics cup and to discuss the way of failure through the exam of...
متن کاملEffects of hydroxyapatite coating of cups used in hip revision arthroplasty
BACKGROUND AND PURPOSE Coating of acetabular revision implants with hydroxyapatite (HA) has been proposed to improve ingrowth and stability. We investigated whether HA coating of revision cups can reduce the risk of any subsequent re-revision. METHODS We studied uncemented cups either with or without HA coating that were used at a primary acetabular revision and registered in the Swedish Hip ...
متن کاملNo superior performance of hydroxyapatite-coated acetabular cups over porous-coated cups
BACKGROUND AND PURPOSE Hydroxyapatite (HA) coating is believed to improve bone-implant ingrowth and long-term survival of prostheses. Recent studies, however, have challenged this view. Furthermore, HA particles may produce third-body wear and initiate aseptic loosening of implants. We report the performance of HA- and porous-coated acetabular cups in a prospective randomized trial. METHODS T...
متن کامل