How Accurate Are Home Blood Pressure Devices in Use? A Cross-Sectional Study

نویسندگان

  • Marcel Ruzicka
  • Ayub Akbari
  • Eva Bruketa
  • Jeanne Françoise Kayibanda
  • Claude Baril
  • Swapnil Hiremath
چکیده

BACKGROUND Out of office blood pressure measurements, using either home monitors or 24 hour ambulatory monitoring, is widely recommended for management of hypertension. Though validation protocols, meant to be used by manufacturers, exist for blood pressure monitors, there is scant data in the literature about the accuracy of home blood pressure monitors in actual clinical practice. We performed a chart review in the blood pressure assessment clinic at a tertiary care centre. METHODS We assessed the accuracy of home blood pressure monitors used by patients seen in the nephrology clinic in Ottawa between the years 2011 to 2014. We recorded patient demographics and clinical data, including the blood pressure measurements, arm circumference and the manufacturer of the home blood pressure monitor. The average of BP measurements performed with the home blood pressure monitor, were compared to those with the mercury sphygmomanometer. We defined accuracy based on a difference of 5 mm Hg in the blood pressure values between the home monitor and mercury sphygmomanometer readings. The two methods were compared using a Bland-Altman plot and a student's t-test. RESULTS The study included 210 patients. The mean age of the study population was 67 years and 61% was men. The average mid-arm circumference was 32.2 cms. 30% and 32% of the home BP monitors reported a mean systolic and diastolic BP values, respectively, different from the mercury measurements by 5 mm Hg or more. There was no significant difference between the monitors that were accurate versus those that were not when grouped according to the patient characteristics, cuff size or the brand of the home monitor. CONCLUSIONS An important proportion of home blood pressure monitors used by patients seen in our nephrology clinic were inaccurate. A re-validation of the accuracy and safety of the devices already in use is prudent before relying on these measurements for clinical decisions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of stress on the rise of blood pressure

Background: The virtual rise of blood pressure resulted from stress, that is observed in subjects that are tested in medical centers, can be oftenly corrected by holter. This phenomenon causes such persons not to response to the common anti blood pressure treatments (2). Materials and methods: This descriptive study was conducted 2006-2007 at the heart clinic of Shohadaye–Ashayer hospital in Kh...

متن کامل

Can validated wrist devices with position sensors replace arm devices for self-home blood pressure monitoring? A randomized crossover trial using ambulatory monitoring as reference.

BACKGROUND Electronic devices that measure blood pressure (BP) at the arm level are regarded as more accurate than wrist devices and are preferred for home BP (HBP) monitoring. Recently, wrist devices with position sensors have been successfully validated using established protocols. This study assessed whether HBP values measured with validated wrist devices are sufficiently reliable to be use...

متن کامل

Validation of Omron RS8, RS6, and RS3 home blood pressure monitoring devices, in accordance with the European Society of Hypertension International Protocol revision 2010

BACKGROUND Allowing patients to measure their blood pressure at home is recognized as being of clinical value. However, it is not known how often these measurements are taken correctly. Blood pressure monitors for home use fall into two types based on the position of the cuff, ie, at the upper arm or the wrist. The latter is particularly convenient, as measurements can be taken fully clothed. T...

متن کامل

عوامل خطر ساز ابتلا به زخم فشاری در بیماران دارای ضایعه مغزی - نخاعی بستری در منزل

Background: Critically ill brain-spinal cord injured patients are at high risk for pressure ulcers. The aim of this study was to investigate risk factors of developing pressure ulcers in critically ill patients with brain-spinal cord injuries. Methods: This cross-sectional study was conducted on 62 home care patients with brain-spinal cord injuries in Hamadan city in 2012. For three weeks, ev...

متن کامل

The Role of Packet Tracer in Learning Wireless Networks and Managing IoT Devices

Wireless networks, Internet of Things (IoT), Internet of Everything (IoE), and smart homes have become extremely important terms in our present-day life. Most of the buildings, companies, institutions, and even homes depend onthese technologies for interaction, communication, automation, and everything surrounding humans. To understand the advanced topics in wireless networks and IoT devi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016