Investigating the benefits of multi-echo EPI for fMRI at 7 T

نویسندگان

  • Benedikt A. Poser
  • David G. Norris
چکیده

Functional MRI studies on humans with BOLD contrast are increasingly performed at high static magnetic field in order to exploit the increased sensitivity. The downside of high-field fMRI using the gradient-echo echo-planar imaging (GE-EPI) method is that images are typically very strongly affected by image distortion and signal loss. It has been demonstrated at 1.5 T and 3 T that image artifacts can be reduced and functional sensitivity simultaneously increased by the use of parallel-accelerated multi-echo EPI. Using sensitivity measurements and an activation study with a cognitive Stroop task experiment (N=7) we here investigate the potential of this method at 7 T. The main findings are: (a) image quality compared to a conventional acquisition scheme is drastically improved; (b) according to CNR estimations the average BOLD sensitivity increases by 6.1+/-4.3% and 13.9+/-5.5% for unweighted and CNR-weighted echo summation, respectively; (c) both functional signal changes and sensitivity in the multi-echo data do not exhibit a pronounced dependence on TE. The consequence is that (d) in practice the performance of simple echo summation at very high field is comparable to that based on a CNR filter. Finally, (e) temporal noise observed in the different echo time courses is not strongly correlated, thus explaining why echo summation is advantageous. The results at typical spatial resolution show that multi-echo EPI acquisition leads to considerable artifact reduction and sensitivity gains, making it superior to conventional GE-EPI for fMRI at 7 T.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Sensory Pathways in Spinal Cord by Comparison of fMRI Methodologies

Introduction: Today, clinicians and neuroscientists need to have a comprehensive survey of neurological pathologies and injuries. For the First-time, SEEP contrast and Spin-Echo pulse sequences was used for functional imaging of the Lumbar spinal cord. This method used by several research groups for Spinal cord mapping, but other researchers tried to improve BOLD fMRI to Spina...

متن کامل

Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI

Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...

متن کامل

A Multi-Resolution Comparison of Single-Shot EPI, 3DFFE and PRESTO for fMRI at 7T

INTRODUCTION Single-shot Echo-Planar Imaging (EPI) is the sequence most commonly used for fMRI experiments. At high field, e.g. 7T, magnetic field inhomogeneities cause spins to become out of phase quickly, and distortion and signal dropout become severe [1]. Consequently, single-shot EPI fMRI suffers technical limitations at high field. Here we consider two alternatives to EPI for high field f...

متن کامل

Integrating fMRI data into 3D conventional radiotherapy treatmentplanning of brain tumors

Introduction: This study was aimed to investigate the beneficial effects of functional magnetic resonance imaging (fMRI) data in treatment planning for patients with CNS tumors in order to decrease the injury of functional regions of the brain followed by increase in life quality and survival of patients. This study pursues a novel approach in planning for the treatment of brai...

متن کامل

Sub-millimeter T2 weighted fMRI at 7 T: comparison of 3D-GRASE and 2D SE-EPI

Functional magnetic resonance imaging (fMRI) allows studying human brain function non-invasively up to the spatial resolution of cortical columns and layers. Most fMRI acquisitions rely on the blood oxygenation level dependent (BOLD) contrast employing T(*) 2 weighted 2D multi-slice echo-planar imaging (EPI). At ultra-high magnetic field (i.e., 7 T and above), it has been shown experimentally a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 45 4  شماره 

صفحات  -

تاریخ انتشار 2009