The Comparative Study of Refractive Index Variations between Haigis, Srk/T and Hoffer-Q Formulas Used for Preoperative Biometry Calculation in Patients with the Axial Length >25 mm

نویسندگان

  • Hasan Razmjoo
  • Hosein Atarzadeh
  • Neda Kargar
  • Mohammad Behfarnia
  • Kobra Nasrollahi
  • Ali Kamali
چکیده

BACKGROUND To compare refractive index variation between Hoffer-Q, Haigis and SRK/T formulas used for preoperative biometry calculation in patients with axial length >25 mm, undergoing cataract surgery. MATERIALS AND METHODS This is a randomized clinical trial study was performed on 54 eyes of 54 patients with ages of 40-70 years old and axial length >25 mm classified into three groups that their IOL POWER were calculated by Haigis, SRK/T and Hoffer-Q formulas before undergoing cataract surgery. Their refractive index variations were calculated from the difference between predicted refractive error formula and actual post-operative refractive error formula. The collected data was entered in SPSS software and was analyzed by ANOVA and Chi-square statistical test. RESULTS With comparison sphere, astigmatism and spherical equivalent indexes before and after of cataract surgery between Haigis, SRK/T, and Hoffer-Q formulas, statistically significant differences were found between the mean of sphere and SE indexes in patients with use of Haigis and SRK/T formulas that have been more favorable post-operative refraction. CONCLUSIONS Haigis formula and then, with slight difference, SRK/T formula have better and more acceptable post-operative refraction results than Hoffer-Q formula in patients with high axial myopia. Therefore, it is recommended using Haigis and SRK/T formulas for IOL power calculation in patients with high axial myopia undergoing cataract surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular Lens Power Calculation Using IOLMaster and Various Formulas in Short Eyes

PURPOSE To evaluate the predictability of intraocular lens (IOL) power calculations using the IOLMaster and four different IOL power calculation formulas (Haigis, Hoffer Q, SRK II, and SRK/T) for cataract surgery in eyes with a short axial length (AL). METHODS The present study was a retrospective comparative analysis which included 25 eyes with an AL shorter than 22.0 mm that underwent uneve...

متن کامل

Accuracy of Intraocular Lens Power Formulas Involving 148 Eyes with Long Axial Lengths: A Retrospective Chart-Review Study

Purpose. This study aims to compare the accuracy of intraocular lens power calculation formulas in eyes with long axial lengths from Chinese patients subjected to cataract surgery. Methods. A total of 148 eyes with an axial length of >26 mm from 148 patients who underwent phacoemulsification with intraocular lens implantation were included. The Haigis, Hoffer Q, Holladay 1, and SRK/T formulas w...

متن کامل

Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes.

Purpose. To evaluate and compare the accuracy of different intraocular lens (IOL) power calculation formulas for eyes with an axial length (AL) greater than 26.00 mm. Methods. This study reviewed 407 eyes of 219 patients with AL longer than 26.0 mm. The refractive prediction errors of IOL power calculation formulas (SRK/T, Haigis, Holladay, Hoffer Q, and Barrett Universal II) using User Group f...

متن کامل

The effect of ocular biometric factors on the accuracy of various IOL power calculation formulas

BACKGROUND To evaluate how differences in ocular biometry affects the Hoffer Q, Holladay 1, SRK/T, and Haigis intraocular lens power calculation formulae predictions. METHODS This study was performed on 91 eyes of 91 patients who underwent uneventful cataract surgery. Ocular biometry values were measured using the IOL Master 500, and intraocular lens (IOL) power was calculated using the Haigi...

متن کامل

Effect of anterior chamber depth on the choice of intraocular lens calculation formula

PURPOSE To investigate the effect of anterior chamber depth (ACD) on the refractive outcomes of the SRK/T, Holladay 1, Hoffer Q and Haigis formulae in short, normal, long and extremely long eyes. METHODS This retrospective study involved patients who had uncomplicated cataract surgery. Preoperative axial length (AL) was divided into four subgroups: short (< 22.00 mm), normal (22.00-24.49 mm),...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017