Comparison of an automated confrontation testing device versus finger counting in the detection of field loss.
نویسندگان
چکیده
PURPOSE The aim of this study was to compare an automated confrontation visual field testing (ACV) device with traditional finger-counting confrontation visual field testing (FCV). METHODS Forty-five eyes of 45 subjects with glaucoma, 5 eyes of 5 subjects with neurologic disease and 15 eyes of 15 normal subjects (age matched to the subjects with glaucoma by frequency) were tested on both ACV and FCV. All subjects with glaucoma and neurologic disease had visual field loss on white-on-white Humphrey perimetry (HVF). The FCV was performed in 8 meridians in a normally lighted room, whereas ACV was performed in a darkened room. The ACV device consisted of a black rectangular box with 4 1.0-mm red light-emitting diodes at each corner and a fixation hole at the center. Four automated randomized presentations were presented, and the subject was asked to identify the number of red lights seen (from 1 to 4). Any point missed on any of the presentations on either test was recorded as a failure. RESULTS All normal subjects passed both tests. FCV detected field loss in 33.0% of glaucomatous eyes, whereas ACV detected field loss in 58% of glaucomatous eyes (P < 0.001). Subjects with glaucoma who passed FCV but failed ACV had an average mean deviation of -7.77 dB on HVF, compared with subjects who failed both FCV and ACV, who had an average mean deviation of -19.74 dB on HVF (P < 0.001). All subjects with absolute visual field loss because of advanced glaucoma or neurologic disease failed both tests. No subject who passed ACV failed FCV. CONCLUSIONS Gross confrontation visual field testing using an automated testing device has a greater sensitivity in the detection of moderate visual field loss than finger counting confrontation visual fields.
منابع مشابه
Diagnostic accuracy of confrontation visual field tests.
OBJECTIVE To determine the diagnostic accuracy of confrontation visual field testing and to compare the accuracy of confrontation tests both individually and in combination. METHODS Patients were prospectively recruited from ophthalmology clinics over a 6-month period. All patients underwent SITA-standard 24-2 Humphrey visual field analysis. Two examiners, masked to the automated perimetry re...
متن کاملDesign and Implementation of an Automated Dispensing Device for Reducing Methadone Therapy Misuse
Introduction: A variety of (deliberate or inaccurate) errors in drug rehabilitation clinics may occur due to use of addictive drugs. Automated drug distribution systems play a significant role in reducing drug medication errors. Method: Firstly, according to the addiction rehabilitation centers requests, the design and construction of the device was performed. The prototype systems were examin...
متن کاملUse of a portable head mounted perimetry system to assess bedside visual fields.
AIM This study was designed to test the ability of a portable computer driven, head mounted visual field testing system to perform automated perimetry on patients at their bedside and to compare these results with the "gold standard" for bedside examinations, confrontation visual fields. METHODS The Kasha visual field system is a portable automated perimeter which utilises a virtual reality h...
متن کاملNew electrical device for field coincidence quality control test in linear accelerators
Testing of the coincidence of a linear accelerators X-ray field and the light field as a quality control test is often done in a subjective method, involving the manual marking of pieces of film and the visual inspection of the film after irradiation. The purpose of this study was to develop an objective method for performing this test, while also increasing the accuracy, precision and the spee...
متن کاملComparison between conventional PCR and PCR - ELISA for detection of Brucella melitensis
Molecular detection techniques are believed to be key tools for both prevention and treatment follow up of brucellosis within live stock and human beings. Consequently rapid, reliable, easy to perform and automated systems for Brucella detection are urgently needed to allow early diagnosis and adequate antibiotic therapy in time. Brucellosis is a worldwide re-emerging zoonosis causing high econ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optometry
دوره 78 8 شماره
صفحات -
تاریخ انتشار 2007