[Fitting Monocurve and Bicurve (Soper-McGuire design) rigid gas-permeable contact lenses in keratoconus patients: a prospective randomized comparative clinical trial].

نویسندگان

  • Cleusa Coral-Ghanem
  • Milton Ruiz Alves
چکیده

PURPOSE To evaluate the clinical performance of Monocurve and Bicurve (Soper-McGuire design) rigid gas-permeable contact lens fitting in patients with keratoconus. METHODS A prospective and randomized comparative clinical trial was conducted with a minimum follow-up of six months in two groups of 63 patients. One group was fitted with Monocurve contact lenses and the other with Bicurve Soper-McGuire design. Study variables included fluoresceinic pattern of lens-to-cornea fitting relationship, location and morphology of the cone, presence and degree of punctate keratitis and other corneal surface alterations, topographic changes, visual acuity for distance corrected with contact lenses and survival analysis for remaining with the same contact lens design during the study. RESULTS During the follow-up there was a decrease in the number of eyes with advanced and central cones fitted with Monocurve lenses, and an increase in those fitted with Soper-McGuire design. In the Monocurve group, a flattening of both the steepest and the flattest keratometric curve was observed. In the Soper-McGuire group, a steepening of the flattest keratometric curve and a flattening of the steepest keratometric curve were observed. There was a decrease in best-corrected visual acuity with contact lens in the Monocurve group. Survival analysis for the Monocurve lens was 60.32% and for the Soper-McGuire was 71.43% at a mean follow-up of six months. CONCLUSIONS This study showed that due to the changes observed in corneal topography, the same contact lens design did not provide an ideal fitting for all patients during the follow-up period. The Soper-McGuire lenses had a better performance than the Monocurve lenses in advanced and central keratoconus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Descriptive analysis of the type and design of contact lenses fitted according to keratoconus severity and morphology.

PURPOSE Keratoconus is characterized by bilateral asymmetrical corneal ectasia that leads to inferior stromal thinning and corneal protrusion. There is currently a lack of consensus regarding the most efficacious method for fitting contact lenses in patients with keratoconus, given the various topographical patterns and evolution grades observed in affected populations. The purpose of the prese...

متن کامل

Contact lenses fitting after intracorneal ring segments implantation in keratoconus.

PURPOSE Evaluate contact lenses fitting after intracorneal ring implantation for keratoconus, its visual acuity and comfort. METHODS Retrospective study of patients undergoing contact lenses fitting, after intracorneal ring for keratoconus. The criterion for contact lens fitting was unsatisfactory visual acuity with spectacle correction as referred by the patients. All patients were intoleran...

متن کامل

Visual rehabilitation with new-age rigid gas-permeable scleral contact lenses--a case series.

INTRODUCTION Primary ectatic corneal diseases usually require rigid gas-permeable (RGP) corneal contact lens wear for visual rehabilitation. As the disease progresses, it becomes increasingly difficult to fit these lenses. RGP scleral contact lenses now provide another treatment option before resorting to surgery. CLINICAL PICTURE Two patients with pellucid marginal degeneration and one with ...

متن کامل

[Hybrid material contact lens in keratoconus and myopic astigmatism patients].

PURPOSE To evaluate comfort and visual performance in relation to two different used contact lens types: hybrid material (HM) and rigid-gas-permeable (RGP), in patients with regular myopic astigmatism and with keratoconus. METHODS A randomized, double masked, prospective study of 22 patients with the diagnosis of myopic astigmatism (8 with myopic astigmatism and 14 with keratoconus) was condu...

متن کامل

Contact lenses as the best conservative treatment of newly diagnosed keratoconus--epidemiological retrospective study.

Keratoconus is a progressive, non-inflammatory corneal ectasia characterized by thinning and weakening of the corneal stroma which results in its' protrusion. The onset is during puberty and progresses until the fourth decade of life. In earlier stages, good visual acuity can be provided with spectacles. With progression, contact lenses are considered to be a better therapy. Aim of this study w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de oftalmologia

دوره 71 3  شماره 

صفحات  -

تاریخ انتشار 2008