Measurement of relative blood volume changes during haemodialysis: merits and limitations.

نویسندگان

  • Judith J Dasselaar
  • Roel M Huisman
  • Paul E de Jong
  • Casper F M Franssen
چکیده

Dialysis hypotension is estimated to occur in 20% of haemodialysis (HD) sessions [1] and can lead to serious vascular complications such as cerebral infarction and cardiac and mesenteric ischaemia [2,3]. It may contribute to chronic overhydration due to an inability to reach dry weight and may lead to under-dialysis [1,2,4]. Prevention of dialysis hypotension, therefore, is an important challenge to the dialysis staff. The initiating factor in the pathogenesis of dialysis hypotension is a decrease in blood volume which results from the imbalance between the ultrafiltration rate and the plasma refilling rate [5]. Devices that continuously and non-invasively monitor relative blood volume (RBV) changes during HD are being advocated as a tool to maintain an adequate volume of the intravascular compartment in order to avoid dialysis hypotension [6–8]. Nowadays, most manufacturers have incorporated an RBV monitor in their dialysis apparatus, but evidence-based knowledge on how to use the RBV data in order to optimize the dialysis prescription of the individual patient is lacking. Moreover, there are conflicting data in the literature on the predictive value of RBV changes for the occurrence of dialysis hypotension. In this review, we will outline the pathophysiological response to ultrafiltration-induced reductions in blood volume, evaluate the RBVmeasuringmethods, discuss the relationship between RBV changes and blood pressure and discuss several factors that influence the validity of RBV measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Merits and limitations of continuous blood volume monitoring during haemodialysis. Summary of the EDTNA/ERCA Journal Club discussion: Winter 2005.

The discussion explored and expanded on the issues raised by Dasselaar et al in their review of the measurement of relative blood volume (RBV) changes during dialysis (NDT 2005). Dialysis machines incorporating blood volume monitoring and control are widely available in Europe. The use of continuous blood volume monitoring (CBVM) to help establish dry weight; problems with CBVM due to connectio...

متن کامل

Optimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement

Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...

متن کامل

Variability of relative blood volume during haemodialysis?

BACKGROUND A decrease in blood volume is thought to play a role in dialysis-related hypotension. Changes in relative blood volume (RBV) can be assessed by means of continuous haematocrit measurement. We studied the variability of RBV changes, and the relation between RBV and ultrafiltration volume (UV), blood pressure, heart rate, and inferior caval vein (ICV) diameter. METHODS In 10 patients...

متن کامل

Specific effect of the infusion of glucose on blood volume during haemodialysis.

BACKGROUND Intradialytic morbid events such as hypotension and cramps during haemodialysis are generally treated by infusion of iso- or hypertonic solutions. However, differences may exist between solutions with respect to plasma refilling and vascular reactivity. METHODS We compared the effect of no infusion (NI) with isovolumetric infusion of isotonic saline 0.9% (IS), saline 3% (HS), isoto...

متن کامل

Renin, blood volume and response to saralasin in patients on chronic haemodialysis: evidence against volume- and renin-'dependent' hypertension.

1. No significant relationship was found be­ tween blood pressure and blood volume, sulphate space or plasma angiotensin II concentration in 59 non-nephrectomized haemodialysis patients, of whom 42 were hypertensive. Supine mean blood pressure was only weakly correlated with plasma renin activity and the correlation was not improved when blood pressure was related to expressions combining renin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 20 10  شماره 

صفحات  -

تاریخ انتشار 2005