The reliability of fetal MRI in the assessment of brain malformations.

نویسندگان

  • Nora Frick
  • Claudius Fazelnia
  • Kathrin Kanzian
  • Wolfgang Hitzl
  • Thorsten Fischer
  • Rosemarie Forstner
  • Gerhard Bogner
چکیده

OBJECTIVES To assess the inter- and intraobserver reliability of different fetal MRI measurements in cases of fetal brain malformations and to examine the concordance between ultrasonography (US) and MRI findings. METHODS Fetal brain MRIs and US findings of 56 pregnant women were retrieved from the institutional database. Standardized fetal brain MRI measurements were performed by 4 observers, and the inter- and intraobserver reliability was determined. Additionally, US and MRI findings were retrospectively compared. RESULTS The interobserver intraclass correlation coefficient (ICC) was above 0.9 for the cerebellum and posterior horn of the lateral ventricle. The measurements regarding the third ventricle (0.50), the fourth ventricle (0.58), and the corpus callosum (0.63) showed poor reliability. Overall, the intraobserver reliability was greater than the interobserver reliability. US and MRI findings were discordant in 29% of the cases with MRI rendering an extended diagnosis in 18%, a change of diagnosis in 3.6%, and excluding pathological findings suspected on US in 7.1%. CONCLUSIONS Fetal MRI is a valuable complement to US in the investigation of fetal brain malformations. The reliability of most parameters was high, except for the measurements of the third and fourth ventricles and the corpus callosum.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

P-26: The Effects of Interferon-Gamma onCarbamazepine-Induced Fetal Malformations inMouse Fetus

Background: One in every 250 newborns is exposed to antiepileptic drugs, inutero .The risk of congenital malformations in newborns, prenatally exposed to antiepileptic drugs (AEDs), is around 5% which is 2 to 2.5 times that of general population; while carbamazepine (CBZ) and valproate (VPA) still provide the treatment of choice in most forms of epilepsy, being efficacious in approximately two-...

متن کامل

18F-FDG PET/CT usefulness vs Tc99m-Tetrofosmin in the assessment of malignant brain gliomas: Report of two cases

Gliomas account for almost 80% of primary malignant brain tumors in adults. Magnetic Resonance imaging (MRI) is still the gold standard for diagnosis of brain tumors and brain 99mTc-tetrofosmin Single Photon Emission Computed Tomography (99mTc-tetrofosmin-SPECT) has been established as a useful tool for their evaluation. Fluorine-18–2-fluoro-2-deoxy-d-glucose positron emi...

متن کامل

Cerebral Palsy and Patterns of Magnetic Resonance Imaging (MRI): A Review

Cerebral Palsy is the most common chronic motor disorder of childhood, that affecting approximately 3 infants per 1000 live-births. The risk of brain injuries that potentially cause Cerebral Palsy has amplified with increasing in survival rates for preterm infants. In addition Cerebral Palsy has a huge economic impact, to immeasurable health, social, and psychological problems that affected chi...

متن کامل

مقایسه یافته های سونوگرافیک و MRI در ناهنجاری های جنینی

Background and purpose: Ultra sonography is the method of choice in pre-natal diagnosis of fetal anomalies however, sonography has limitations in oligohydramnios, maternal obesity and complex fetal anomalies. MRI, is a method with high contrast resolution, large FOV for fetus, placenta and uterine, along with multiplanar images. The aim of our study is to compare the sonographic and MRI findi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Fetal diagnosis and therapy

دوره 37 2  شماره 

صفحات  -

تاریخ انتشار 2015