Correlations between laser flare measurements and anterior chamber protein concentrations.
نویسندگان
چکیده
The laser flare cell meter quantifies anterior chamber (AC) protein (flare) by measuring light scattering of a helium-neon laser beam in the AC. The relationship between photon count and protein concentration both in vitro and in vivo was assessed. The reproducibility of the in vitro photon count measurements was 7.3%. There was a significant linear relationship between photon count and the concentration of both albumin (r = 1.0, P = 0.0001) and immunoglobulin G (IgG, r = 0.99, P = 0.0001) in vitro, but the linear-regression formulas were different with greater light scattering by IgG than by albumin at the same concentration. Laser flare measurements were done on 22 patients (12 normal eyes, 5 eyes with Fuchs' heterochromic cyclitis, and 5 uveitic eyes) before cataract surgery. Aqueous humor obtained from these patients by paracentesis was analyzed for total protein, albumin, and IgG concentration. There was a significant linear relationship (r = 0.88, P = 0.0001) between the laser flare value (range, 5.8-107.8 photons/msec) and the total aqueous protein concentration (range, 14-388 mg/dl). Use of an in vitro albumin calibration curve to convert photon count into protein concentration was found to overestimate the actual protein concentration. This overestimation was slight in normal eyes and increased with increased blood-aqueous barrier breakdown. The use of such a calibration curve therefore is not appropriate in studies on diseased eyes. The authors recommended that laser flare results be expressed in either photons per milliseconds or converted into an equivalent protein concentration using a calibration curve based on actual AC protein measurements.
منابع مشابه
A Rayleigh Scatter-Based Ocular Flare Analysis Meter for Flare Photometry of the Anterior Chamber.
PURPOSE Existing flare photometers are based on the Tyndall effect, which requires sophisticated laser photometry. The ocular flare analysis meter (OFAM) is a nonlaser photometer that uses quantitative Rayleigh scatter and absorption from visible light to compute a flare value. This study is designed to correlate OFAM measurements with qualitative measurements of flare in vitro and in vivo. M...
متن کاملA comparison of the laser flare cell meter and fluorophotometry in assessment of the blood-aqueous barrier.
PURPOSE To evaluate and compare the use of the Kowa laser flare cell meter and intravenous anterior chamber fluorophotometry in assessment of the blood-aqueous barrier after cataract surgery. METHOD Laser flare and cell measurements and fluorophotometry were performed at 1 and 3 months after surgery in 48 eyes of 44 patients admitted for routine cataract surgery. The fellow pseudophakic eyes ...
متن کاملRelationships between laser flare photometry values and complications of uveitis.
OBJECTIVE To determine whether relationships exist between elevated laser flare photometry values and common abnormalities and complications associated with uveitis. METHODS We retrospectively studied all patients with uveitis on whom laser flare photometry measurements ("flare") were obtained (N = 111) at 2 academic medical centers. The first laser flare photometry values obtained for each p...
متن کاملAnterior chamber flare after trabeculectomy and after phacoemulsification.
AIMS To evaluate and compare prospectively the anterior chamber inflammatory response after phacoemulsification cataract surgery and after trabeculectomy with peripheral iridectomy. METHODS Anterior chamber inflammation was measured using the Kowa FM-500 laser flare meter in 131 patients undergoing trabeculectomy and 148 patients undergoing phacoemulsification cataract extraction with intraoc...
متن کاملChanges in anterior chamber flare and cells following cataract surgery.
The laser flare cell meter allows rapid non-invasive quantification of aqueous flare and cells. In this prospective study laser photometry was used to document the recovery of the blood-aqueous barrier in 27 normal eyes following cataract surgery. Aqueous flare and cells were highest on the first postoperative day, declining rapidly in the first week and returning to preoperative levels by 3 mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 33 10 شماره
صفحات -
تاریخ انتشار 1992