Voltammetric Characteristics and Application in Batch Injection Analysis with Amperometric Detection

نویسندگان

  • Ana Maria Oliveira
  • Brett
  • Frank-Michael Matysik
  • M. Teresa Vieira
چکیده

Thin-film gold electrodes were produced by radio-frequency sputtering using a polyvinyl chloride foil as substrate. The voltammetric behavior was characterized in various electrolyte solutions. In alkaline and neutral aqueous solutions reliable voltammetric measurements can be performed while in acidic media some nondefined phenomena occur. A novel type of electrode for batch injection analysis (BIA) is presented which is produced from circular pieces of the thin-film material. This electrode can be used for BIA in conventional voltammetric cells. Pulsed amperometric detection is demonstrated to be viable with thin-film gold electrodes and shows analytical advantages over constant-potential detection in the BIA of hydrogen peroxide.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of selected phenolic acids in beer extract by liquid chromatography with voltammetric-amperometric detection.

A voltammetric-amperometric detector for liquid chromatography based on a dual electrode electrochem-ical cell has been developed. This detector enables voltammograms to be obtained without the charging current problems inherent in single electrode voltammetric detectors. The detector is operated by scanning the potential of the upstream (voltammetric) electrode and detecting the electrolysis p...

متن کامل

Batch-injection analysis with amperometric detection of the DPPH radical for evaluation of antioxidant capacity.

This work proposes the application of batch-injection analysis with amperometric detection to determine the antioxidant capacity of real samples based on the measurement of DPPH radical consumption. The efficient concentration or EC50 value corresponds to the concentration of sample or standard required to scavenge 50% DPPH radicals. For the accurate determination of EC50, samples were incubate...

متن کامل

Flow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine

A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detec...

متن کامل

Investigation of amperometric detection of phosphate Application in seawater and cyanobacterial biofilm samples.

Detection of phosphate using amperometry was investigated. The phosphomolybdate complex, formed by addition of nitric acid, ammonium molybdate and phosphate, was reduced at a carbon paste electrode polarised at +0.3V (versus Ag/AgCl). The major characteristics observed were simplicity of the equipment, a limited consumption of reagents and a low detection limit (0.3mumoll(-1)), with a linear ra...

متن کامل

Rapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies

A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enabl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004