Impact of Coronary Plaque Characteristics on Late Stent Malapposition after Drug-Eluting Stent Implantation.
نویسندگان
چکیده
PURPOSE To evaluate the impact of pre-procedural coronary plaque composition assessed by virtual histology intravascular ultrasound (VH-IVUS) on late stent malapposition assessed by optical coherence tomography (OCT) following drug-eluting stent (DES) implantation. MATERIALS AND METHODS The study population consisted of 121 patients (121 lesions) who underwent both pre-procedural VH-IVUS and follow-up OCT after DES implantation. The association between pre-procedural plaque composition [necrotic core (NC), dense calcium (DC), fibrotic (FT), and fibro-fatty (FF) volumes] assessed by VH-IVUS and late stent malapposition (percent malapposed struts) or strut coverage (percent uncovered struts) assessed by follow-up OCT was evaluated. RESULTS Pre-procedural absolute total NC, DC, FT, and FF plaque volumes were 22.9±19.0, 7.9±9.6, 63.8±33.8, and 16.5±12.4 mm³, respectively. At 6.3±3.1 months post-intervention, percent malapposed and uncovered struts were 0.8±2.5% and 15.3±16.7%, respectively. Pre-procedural absolute total NC and DC plaque volumes were positively correlated with percent malapposed struts (r=0.44, p<0.001 and r=0.45, p<0.001, respectively), while pre-procedural absolute total FT plaque volume was weakly associated with percent malapposed struts (r=0.220, p=0.015). Pre-procedural absolute total DC plaque volume was the only independent predictor of late stent malapposition on multivariate analysis (β=1.12, p=0.002). There were no significant correlations between pre-intervention plaque composition and percent uncovered struts. CONCLUSION Pre-procedural plaque composition was associated with late stent malapposition but not strut coverage after DES implantation. Larger pre-procedural absolute total DC plaque volumes were associated with greater late stent malapposition.
منابع مشابه
Incidences, predictors, and clinical outcomes of acute and late stent malapposition detected by optical coherence tomography after drug-eluting stent implantation.
BACKGROUND We investigated the incidences, predictors, and clinical outcomes of acute and late stent malapposition detected by optical coherence tomography (OCT) after drug-eluting stent implantation. METHODS AND RESULTS We analyzed the OCT images from 351 patients with 356 lesions who received poststent and follow-up OCT examinations. Acute stent malapposition was observed in 62% of lesions....
متن کاملBackground incidence of late malapposition after bare-metal stent implantation.
BACKGROUND Late stent malapposition has been reported to be an abnormal finding after vascular brachytherapy and, possibly, implantation of drug-eluting stents. It can only be detected if intravascular ultrasound (IVUS) is performed at follow-up. However, the "background" frequency of late stent malapposition after bare-metal stent implantation is not known. METHODS AND RESULTS We studied 206...
متن کاملCoronary Aneurysm Occurring Late after Drug-Eluting Stent Implantation
Drug-eluting stents may affect the normal healing process of the vessel wall and the remodeling process and may lead to late stent malapposition (LSM). The known incidence of this phenomen originates from short-term angiographic follow-up studies. We describe a case report of very late stent malapposition and marked positive vessel remodeling 3 years after sirolimus-eluting coronary stent impla...
متن کاملPredictors and Long‐Term Clinical Impact of Acute Stent Malapposition: An Assessment of Dual Antiplatelet Therapy With Drug‐Eluting Stents (ADAPT‐DES) Intravascular Ultrasound Substudy
BACKGROUND The impact of acute stent malapposition (ASM) on long-term clinical outcomes in patients undergoing percutaneous coronary intervention is still controversial. We sought to evaluate predictors and long-term clinical outcomes of ASM. METHODS AND RESULTS ADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents) was a prospective multicenter study of 8663 patients un...
متن کاملDrug-eluting stent malapposition and its relationship to drug-eluting stent thrombosis
Stent malapposition (whether acute and persistent, or late and acquired) is common, occurring in 10–20% of drug-eluting stent implantations in stable patients and 30–40% of ST-elevated myocardial infarction patients. Acute stent malapposition is not a predictor of early stent thrombosis. Conversely, late stent malapposition, especially the large late stent malapposition area, might be a cause o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Yonsei medical journal
دوره 56 6 شماره
صفحات -
تاریخ انتشار 2015