Comparison of improved BACTEC and Lowenstein-Jensen media for culture of mycobacteria from clinical specimens.

نویسندگان

  • P Anargyros
  • D S Astill
  • I S Lim
چکیده

A 4-month trial involving 2,563 routine clinical specimens was conducted to compare the improved BACTEC TB system (12B medium) with the conventional Lowenstein-Jensen (LJ) media for the isolation, identification, and susceptibility testing of mycobacteria. One hundred sixty-two mycobacterial isolates were recovered, 147 (91%) with BACTEC and 118 (73%) with LJ media. Of these, 62 were Mycobacterium tuberculosis complex strains, 59 (95%) of which were isolated with BACTEC and 54 (87%) of which were isolated with LJ media. Of the remaining 100 isolates, which were mycobacteria other than tuberculosis (MOTT), BACTEC and LJ media detected 88 and 64%, respectively. The contamination rate was significantly higher in BACTEC (5%) than in LJ media (3.3%). The mean isolation time for M. tuberculosis complex with BACTEC was 15.5 days, compared with 25.6 days with LJ. For MOTT, the mean isolation times were 5.8 and 21.4 days, respectively. Identification of 32 M. tuberculosis complex isolates and 38 isolates of MOTT by the BACTEC NAP (p-nitro-alpha-acetylamino-beta-hydroxypropiophenone) inhibition test gave 100% agreement with conventional biochemical identifications. The results of susceptibility testing of 18 M. tuberculosis complex isolates with BACTEC agreed completely with those obtained by the resistance ratio method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multicenter comparison of ESP Culture System II with BACTEC 460TB and with Lowenstein-Jensen medium for recovery of mycobacteria from different clinical specimens, including blood.

The recently developed ESP Culture System II (AccuMed, Chicago, Ill.) was compared with radiometric BACTEC 460TB (Becton Dickinson, Towson, Md.) and with Lowenstein-Jensen medium for recovery of mycobacteria from over 2,500 clinical specimens both of respiratory and nonrespiratory origin, including blood. The majority of the 219 mycobacterial isolates (129) belonged to the Mycobacterium tubercu...

متن کامل

Use of BACTEC MGIT 960 for recovery of mycobacteria from clinical specimens: multicenter study.

The BACTEC MGIT 960 instrument is a fully automated system that exploits the fluorescence of an oxygen sensor to detect growth of mycobacteria in culture. Its performance was compared to those of the radiometric BACTEC 460 instrument and egg-based Lowenstein-Jensen medium. An identical volume of sample was inoculated in different media, and incubation was carried out for 6 weeks with the automa...

متن کامل

Comparison of recovery rates for mycobacteria from BACTEC 12B vials, Middlebrook 7H11-selective 7H11 biplates, and Lowenstein Jensen slants in a public health mycobacteriology laboratory.

Recovery rates from Middlebrook 7H11-selective 7H11 biplates and Lowenstein-Jensen slants (LJ) used with BACTEC 12B vials were compared for 5,399 specimens. For 578 specimens that were inoculated onto three media, 580 mycobacteria were isolated, including 277 (48%) Mycobacterium avium complex isolates, 230 (40%) Mycobacterium tuberculosis isolates, and 73 (12%) other mycobacteria. For BACTEC 12...

متن کامل

Comparison of the BACTEC MGIT 960 and BACTEC 460TB systems for detection of mycobacteria in clinical specimens.

The reliability of the Mycobacteria Growth Indicator Tube (MGIT) 960 system for rapid detection of mycobacteria in clinical specimens was evaluated and compared to the radiometric method (BACTEC 460TB) and to mycobacterial culture on Lowenstein-Jensen (LJ) medium. Clinical specimens (n = 590) were tested without selection. A total of 121 (20.5%) isolates of mycobacteria were recovered; 98 (81.0...

متن کامل

Comparative evaluation of BACTEC 460TB system and Lowenstein-Jensen medium for the isolation of M. tuberculosis from cerebrospinal fluid samples of tuberculous meningitis patients.

PURPOSE To evaluate the role of the radiometric BACTEC 460TB system and the conventional Lowenstein-Jensen (LJ) medium for isolation of M. tuberculosis from cerebrospinal fluid (CSF) samples of tuberculous meningitis (TBM) patients. METHODS CSF specimens (n=2325) from suspected TBM patients were processed for isolation of mycobacteria by inoculating BACTEC 12B medium and the LJ medium. The is...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 28 6  شماره 

صفحات  -

تاریخ انتشار 1990