Task-specific Multiple-arm Minimally Invasive Surgical Device Design Using Cooperative Kinematic Isotropy Indices

نویسنده

  • Frank L. Hammond
چکیده

The transition from multiple-port to single-port robotic systems in minimally invasive surgery (MIS) procedures has made flexible, dexterous manipulation an essential capability. The requirement that single-port MIS devices span an enclosed surgical workspace through only one access point while avoiding collateral damage to surrounding tissues necessitates the employment of mechanically sophisticated, kinematically redundant device architectures. These redundant architectures, while capable of achieving clinically-acceptable performance levels on complicated MIS procedures, are difficult to design and can easily result in economically prohibitive or technically impractical solutions. The problem of balancing clinical functionality and design economy in single-port MIS devices becomes even more challenging when the dexterous use multiple surgical tools is required for a given procedure. This research presents a design methodology aimed at reducing the number of degrees of freedom needed to achieve dexterous motion for a multiple-arm single-port MIS device. This design methodology exploits the availability of multiple manipulator arms by quantifying device dexterity in terms of cooperative manipulability, such that the dexterity of two or more non-redundant manipulator arms can be synergistically combined to achieve a high level of motion redundancy. This methodology, in theory, can be used to design multiple-arm MIS devices such that each arm is specialized for a particular type of motion, thus obviating the need for more versatile, redundant manipulator arms which innately require higher DOFs and, by extension, demand greater mechanical sophistication and device cost. The concept of cooperative kinematic isotropy, an extension of prior work on weighted global isotropy indices, is developed as a multiple-arm MIS device fitness metric. This metric quantifies kinematic isotropy as the aggregate isotropy of two or more manipulator arms, and allows the treatment surgical procedures as a task-specific, hybrid set of individual and cooperative manipulation tasks. The efficacy of cooperative kinematic isotropy is demonstrated on the design of a fourarmed single-port MIS device designed for blood vessel anastomosis procedures that typically require such a hybrid set of manipulation tasks. Results show that cooperative kinematic isotropy is an effective means reducing MIS device complexity while maintaining adequate levels of kinematic dexterity for specific surgical procedures. The author concludes that this new design fitness metric, while heuristic in nature, holds the potential to improve both the clinical value and the economy of cutting-edge, multiple-armed, single-port MIS systems. Figure 1. MIS DEVICE WITH FOUR MANIPULATOR ARMS

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hybrid analysis of a spherical mechanism for a minimally invasive surgical (MIS) robot--design concepts for multiple optimizations.

Several criteria exist for determining the optimal design for a surgical robot. This paper considers kinematic performance metrics, which reward good kinematic performance, and dynamic performance metrics, which penalize poor dynamic performance. Kinematic and dynamic metrics are considered independently, and then combined to produce hybrid metrics. For each metric, the optimal design is the on...

متن کامل

Task-Space and Null-Space Control Design for Robotic-Assisted Minimally Invasive Surgery

This paper discusses the control design of roboticassisted minimally invasive surgery (MIS) with haptic feedback. The operational space control has a position-position telemanipulation architecture with the phantom in the loop, enabling telepresence in free-space and contact. The null space control guarantees that surgical kinematic constraints are fulfilled. Both task and posture control run a...

متن کامل

Measurement and Optimization of Minimally Invasive Intervention Device Design Fitness Using a Multiobjective Weighted Isotropy Index

The recent transition from multiple-port to single-port systems in minimally invasive intervention (MII) procedures has created a need for more flexible, dexterous robotic manipulation devices capable of spanning an entire surgical workspace without the risk of collateral damage. The design of such devices requires a careful balance of the mechanical complexity needed to facilitate clinical fun...

متن کامل

Kinematic design considerations for minimally invasive surgical robots: an overview.

BACKGROUND Kinematic design is a predominant phase in the design of robotic manipulators for minimally invasive surgery (MIS). However, an extensive overview of the kinematic design issues for MIS robots is not yet available to both mechanisms and robotics communities. METHODS Hundreds of archival reports and articles on robotic systems for MIS are reviewed and studied. In particular, the kin...

متن کامل

Optimization of a Redundant Serial Spherical Mechanism for Robotic Minimally Invasive Surgery

Serial spherical linkages have been used in the design of a number of robots for minimally invasive surgery, in order to mechanically constrain the surgical instrument with respect to the incision. However, the typical serial spherical mechanism suffers from conflicting design objectives, resulting in an unsuitable compromise between avoiding collision with the patient and producing good kinema...

متن کامل