Effects of Responsive Reagents on PT & APTT Testing
نویسنده
چکیده
منابع مشابه
Effect of 3.2% vs 3.8% sodium citrate concentration on routine coagulation testing.
The effects of 3.2% and 3.8% sodium citrate concentration on the results of routine coagulation assays (prothrombin time [PT] and activated partial thromboplastin time [aPTT]) were evaluated by means of two sets of reagents, one responsive and the other nonresponsive. Five groups were entered in the study: healthy volunteers; outpatients receiving stable oral anticoagulant therapy; and hospital...
متن کاملEffects of the oral, direct thrombin inhibitor dabigatran on five common coagulation assays.
Dabigatran is an oral, reversible thrombin inhibitor that has shown promising results in large clinical trials. Laboratory monitoring is not needed but the effects on common coagulation assays are incompletely known. Dabigatran was added to plasma from healthy subjects in the concentration range 0-1,000 μg/l and analysed using several reagents for activated thromboplastin time (APTT), prothromb...
متن کاملEffects of the oral, direct factor Xa inhibitor rivaroxaban on commonly used coagulation assays.
INTRODUCTION Rivaroxaban is an oral direct factor Xa inhibitor developed for prophylaxis and treatment of thromboembolic disorders. Laboratory monitoring is not necessary but the dose-dependent effects on common reagents and assay procedures are largely unknown. OBJECTIVES To investigate the effect of rivaroxaban on commonly used coagulation assays. MATERIALS AND METHODS Rivaroxaban was add...
متن کاملEffects of the oral, direct factor Xa inhibitor apixaban on routine coagulation assays and anti-FXa assays.
INTRODUCTION Apixaban is an oral direct factor Xa inhibitor developed for the prophylaxis and treatment of thromboembolic disorders. Laboratory monitoring is not necessary, but the effects on common coagulation reagents and assays constitute clinically valuable information. OBJECTIVES To investigate the effects of apixaban on commonly used coagulation methods, and to evaluate anti-FXa assays ...
متن کاملA cartridge based sensor array platform for multiple coagulation measurements from plasma.
This paper proposes a MEMS-based sensor array enabling multiple clot-time tests for plasma in one disposable microfluidic cartridge. The versatile LoC (Lab-on-Chip) platform technology is demonstrated here for real-time coagulation tests (activated Partial Thromboplastin Time (aPTT) and Prothrombin Time (PT)). The system has a reader unit and a disposable cartridge. The reader has no electrical...