An original electronic device for compensating ratio and phase-displacement errors, of measuring current transformers and clamp-on probes, is proposed. It is specially intended for low-frequency applications (power frequency and its harmonic components), where the magnetizing current is the main cause of measuring errors. This system reduces the magnetic flux in the transformer core, reducing in this way the magnetizing current. The proposed system even reduces the influence of the error produced by the variation of the burden connected to the secondary winding. Large values of burden can be used without effects on the transformer measuring errors. This device can be directly applied to conventional current transformers, connecting the device to the secondary terminals. It is not necessary to use any auxiliary winding or auxiliary core, or any modification of those transformers.
منابع مشابه
Research on Proximity Magnetic Field Influence in Measuring Error of Active Electronic Current Transformers
The principles of the active electronic current transformer (ECT) are introduced, and the mechanism of how a proximity magnetic field can influence the measuring of errors is analyzed from the perspective of the sensor section of the ECT. The impacts on active ECTs created by three-phase proximity magnetic field with invariable distance and variable distance are simulated and analyzed. The theo...
متن کاملMathematical Proof for the Minimized Stray Fields in Transformers Using Auxiliary Windings Based on State Equations for Evaluation of FEM Results
Stray magnetic field is one of the main issues in design of transformers, since it causes non-ideal behavior of transformers. One of the techniques is usually adopted to mitigate the unwanted stray magnetic field is the use of auxiliary windings creating a magnetic field opposite to the incident one giving rise to the reduction of the total magnetic fields. This paper presents a new mathematica...
متن کاملModeling the Frequency Response Movements in Power Transformers for Predicting Purposes
Power transformers are key components in electrical power supplies and their failure could cause severe consequences on continuity of service and also generates substantial costs. Identifying problems at an early stage, before catastrophic failure occurs, is a great benefit for reliable operation of power transformers. Frequency Response Analysis (FRA) is a new, well-known and powerful diagnost...
متن کاملHarmonic Modeling of Inrush Current in Core Type Power Transformers Using Hartley Transform
This paper presents a new method for evaluation and simulation of inrush current in various transformers using operational matrices and Hartley transform. Unlike most of the previous works, time and frequency domain calculations are conducted simultaneously. Mathematical equations are first represented to compute the inrush current based on reiteration and then Hartley transform is used to stud...
متن کاملDesign Modification of Rogowski Coil for Current Measurement in Low Frequency
The principle object of this paper is to offer a modified design of Rogowski coil based on its frequency response. The improvement of the integrator circuit for nullifying the phase difference between the waveforms of the measured-current and the corresponding terminal voltage is a further object of this investigation. This paper addresses an accurate, yet more efficient measuring and protect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEEE Trans. Instrumentation and Measurement
دوره 49 شماره
صفحات -
تاریخ انتشار 2000