Suture loop to aid in ganciclovir implant removal.

نویسندگان

  • M W MacCumber
  • S Sadeghi
  • J A Cohen
  • T A Deutsch
چکیده

BACKGROUND The ganciclovir implant (Vitrasert; Bausch & Lomb Inc, Claremont, Calif) has been a useful device in the management of cytomegalovirus retinitis. Seven months after placement, implant exchange is often considered. However, removal may be difficult and may result in vitreous hemorrhage or intraocular dislocation. OBJECTIVE To describe a suture loop attached to the implant strut and left in the sub-Tenon space to aid in implant removal. METHODS Twenty-five eyes of 17 patients received a ganciclovir implant with an 8-0 nylon suture loop left beneath the Tenon capsule and underwent at least 6 months of follow-up. Two of these eyes subsequently had a similarly modified ganciclovir implant placed at a separate site (inferonasally) with at least 6 additional months of follow-up. Six eyes of 3 patients had the implant removed as part of an exchange and underwent at least 4 months of follow-up. RESULTS In the 25 eyes, there were no cases of endophthalmitis, wound leak, suture exposure, or other complications. At implant removal in the 6 eyes previously mentioned, the loop was used for traction on the implant and aided in localization of the implant strut. In these 6 eyes, there were no cases of retinal or choroidal detachment, visually significant vitreous hemorrhage, implant dislocation, or other complications. CONCLUSION A sub-Tenon capsule suture loop is well tolerated and can assist in ganciclovir implant removal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A single-suture technique for placement of the ganciclovir implant.

The ganciclovir implant is a surgically implanted sustained-release drug delivery system used for the treatment of cytomegalovirus retinitis. The device is suspended in the vitreous cavity through a pars plana incision. Previous reports of the surgical procedure have described securing the implant on 1 suture, tied with an external knot. The ends of this suture were left long to avoid sharp end...

متن کامل

A systematic review of suture-button versus syndesmotic screw in the treatment of distal tibiofibular syndesmosis injury

BACKGROUND Now, using a suture-button device to treat distal tibiofibular syndesmotic injuries is overwhelming due to its advantages over screw fixation. Current systematic review was conducted to make a comparison between suture-button fixation and traditionally screw fixation in the treatment of syndesmotic injuries. The outcomes included functional outcomes, implant removal, implant failure,...

متن کامل

Patellar Fractures: An Innovative Surgical Technique With Transosseous Suture to Avoid Implant Removal.

PURPOSE To describe a new surgical procedure and its outcomes: osteosynthesis with high-resistance sutures, avoiding metallic implants. Open sky osteosynthesis with Kirschner and cerclage wiring is the current gold standard for patella fractures. Favorable functional outcomes have been observed, although implant removal is required in many cases due to the prominent wires under the skin. New im...

متن کامل

Emergence of drug-resistant cytomegalovirus retinitis in the contralateral eyes of patients with AIDS treated with ganciclovir.

The purpose of the present study was to examine the emergence of ganciclovir-resistant virus in the contralateral eyes of patients who received treatment for cytomegalovirus retinitis with either a ganciclovir implant plus oral placebo, a ganciclovir implant plus oral ganciclovir, or intravenous (iv) ganciclovir. Viral DNA was amplified from vitreous specimens and was assayed for UL97 and UL54 ...

متن کامل

Removal of dental implant displaced into maxillary sinus by combination of endoscopically assisted and bone repositioning techniques: a case report

BACKGROUND Accidental displacement of a dental implant into the maxillary sinus is an infrequent although not uncommon complication encountered in dental clinical practice, with the main cause thought to be inadequate bone height in the posterior maxilla. We report a case of migration of a dental implant into the maxillary sinus, and discuss the benefits of its removal by a combination of endos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 117 9  شماره 

صفحات  -

تاریخ انتشار 1999