A Comparative Study on Predictive and ISVM Direct Torque Control Methods for a Doubly Fed Induction Machine Fed by an Indirect Matrix Converter

نویسندگان

  • M. Aghasi
  • D. A. Khaburi
  • V. Faraji
  • H. Behnia
چکیده

This paper presents a comparative study on the Predictive Direct Torque Control method and the Indirect Space Vector Modulation Direct Torque Control method for a Doubly-Fed Induction Machine (DFIM) which its rotor is fed by an Indirect Matrix Converter (IMC). In Conventional DTC technique, good transient and steady-state performances are achieved but it presents a non constant switching frequency behavior and non desirable torque ripples. However, in this paper by using the proposed methods, a fixed switching frequency is obtained. In this model Doubly-Fed Induction Machine is connected to the grid by the stator and the rotor is fed by an Indirect Matrix Converter. Functionally this converter is very similar to the Direct Matrix Converter, but it has separate line and load bridges. In the inverter stage, the Predictive method and ISVM method are employed. In the rectifier stage, in order to reduce losses caused by snubber circuits, the rectifier fourstep commutation method is employed. A comparative study between the Predictive DTC and ISVM-DTC is performed by simulating these control systems in MATLAB/SIMULINK software environments and the obtained results are presented and verified.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study on Predictive and ISVM Direct Torque Control Methods for a Doubly Fed Induction Machine Fed by an Indirect Matrix Converter

This paper presents a comparative study on the Predictive Direct Torque Control method and the Indirect Space Vector Modulation Direct Torque Control method for a Doubly-Fed Induction Machine (DFIM) which its rotor is fed by an Indirect Matrix Converter (IMC). In Conventional DTC technique, good transient and steady-state performances are achieved but it presents a non constant switching fr...

متن کامل

Active and Reactive Power Management of Wind Farm Based on a Six Leg Tow Stage Matrix Converter Controlled by a Predictive Direct Power Controller

In this paper we propose a new configuration of the wind farm connecting with an electrical grid. The proposed Wind Energy Conversion System (WECS) is based on a two stages six-leg matrix converter using to drive a two Doubly Fed Induction Machines operating at different wind speeds. Each Doubly Fed Induction Generator (DFIG) is controlled through the rotor currents using the Finite Set Model P...

متن کامل

A Combined Vector and Direct Power Control for AC/DC/AC Converters in DFIG Based Wind Turbine

The doubly-fed generators (DFIG) have clear superiority for the applications of large capacity and limited-range speed control case due to the partially rated inverter, lower cost and high reliability. These characteristics enable the doubly-fed wound rotor induction machine to have vast applications in wind-driven generation.In this paper Combined Vector and direct power control (CVDPC) strate...

متن کامل

Matrix Converter Induction Motor Drive Employing Direct Torque Control Method

The presented paper deals with the implementation of the Switching Table Based Direct Torque Control (ST-DTC) in the matrix converter-fed induction motor drive. In order to improve the control of the matrix converter input power factor, the use of the simplified Indirect Space Vector Modulation (ISVM) was proposed. To verify the feasibility of the proposed solution, experimental results were pr...

متن کامل

Novel design and simulation of predictive power controller for a doubly-fed induction generator using rotor current in a micro-hydropower plant

Hydropower plant and especially micro-hydropower plant is an available, reliable and economical energy source. Micro-hydropower plant is one of the most environment-friendly technology, use and development of which leads to reduction of energy consumption sporadically and worldwide. Along with the growth of these power plants, the issues related to the control of electrical parameters such ...

متن کامل