Relative importance of secondary settling tank models in WWTP simulations – A global sensitivity analysis using BSM2
نویسندگان
چکیده
Results obtained in a study using the Benchmark Simulation Model No. 1 (BSM1) show that a one-dimensional secondary settling tank (1-D SST) model structure and its parameters are among the most significant sources of uncertainty in wastewater treatment plant (WWTP) simulations [Ramin et al., 2011]. The sensitivity results consistently indicate that the prediction of sludge production is most sensitive to the variation of the settling parameters. In the present study, we use the Benchmark Simulation Model No. 2 (BSM2), a plant-wide benchmark, that combines the Activated Sludge Model No. 1 (ASM1) with the Anaerobic Digestion Model No. 1 (ADM1). We use BSM2 as a vehicle to compare two different 1-D SST models, and to assess the relative significance of their performance on WWTP simulation model outputs. The two 1-D SST models assessed include the firstorder model by Takács et al. [1991] and the second-order convection-dispersion tool [Plósz et al., 2007]. Additionally, we assess the impact of two operational strategies for excess activated sludge wastage on simulation performance. A global sensitivity analysis (GSA) on BSM2 was carried out using two methods: (a) linear regression of Monte Carlo simulations (SRC method); and (b) Morris screening. The overall objective of assessing the 1-D SST model selection and parameters in GSA is to provide a parameter sensitivity ranking for WWTP calibration exercises, aiming at predicting key plant performance criteria, including methane production and effluent water quality index. Results obtained in this study show that, 1-D SST model parameters strongly influence biogas production via anaerobic digestion and the plant’s effluent water quality, but they have limited effect on estimating the quality of nitrogen rich returns from the digester.
منابع مشابه
Significance of settling model structures and parameter subsets in modelling WWTPs under wet-weather flow and filamentous bulking conditions.
Current research focuses on predicting and mitigating the impacts of high hydraulic loadings on centralized wastewater treatment plants (WWTPs) under wet-weather conditions. The maximum permissible inflow to WWTPs depends not only on the settleability of activated sludge in secondary settling tanks (SSTs) but also on the hydraulic behaviour of SSTs. The present study investigates the impacts of...
متن کاملBenchmark simulation Model no 2 in Matlab-simulink: towards plant-wide WWTP control strategy evaluation.
In this paper, implementation of the Benchmark Simulation Model No 2 (BSM2) within Matlab-Simulink is presented. The BSM2 is developed for plant-wide WWTP control strategy evaluation on a long-term basis. It consists of a pre-treatment process, an activated sludge process and sludge treatment processes. Extended evaluation criteria are proposed for plant-wide control strategy assessment. Defaul...
متن کاملSurvey of indicator toxicity of Isfahan south of wastewater treatment plant by using of daphnia magna
Introduction: Bioassay is necessary for assessment of pollution. Because physical and chemical taste are not enough for assessment of potential effects on water ecosystem. Bioassay tests have alot of scientific value inanition doing of them is easy and need less time, also need less space, laboratory equipment’s and expenditure. Therefor such tests have found special attention in water pollutio...
متن کاملGlobal sensitivity analysis of biochemical, design and operational parameters of the Benchmark Simulation Model no. 2
Wastewater treatment plant control and monitoring can help to achieve good effluent quality, in a complex, highly non-linear process. The Benchmark Simulation Model no. 2 (BSM2) is a useful tool to competitively evaluate plant-wide control on a long-term basis. A key component to characterise the system for control is outputparameter sensitivity. This paper brings the results of a global sensit...
متن کاملPlant-wide (BSM2) evaluation of reject water treatment with a SHARON-Anammox process.
In wastewater treatment plants (WWTPs) equipped with sludge digestion and dewatering systems, the reject water originating from these facilities contributes significantly to the nitrogen load of the activated sludge tanks, to which it is typically recycled. In this paper, the impact of reject water streams on the performance of a WWTP is assessed in a simulation study, using the Benchmark Simul...
متن کامل