Can we use the CO2 concentrations determined by continuous-flow isotope ratio mass spectrometry from small samples for the Keeling plot approach?

نویسندگان

  • Ottmar Joos
  • Matthias Saurer
  • Alexander Heim
  • Frank Hagedorn
  • Michael W I Schmidt
  • Rolf T W Siegwolf
چکیده

A common method to estimate the carbon isotopic composition of soil-respired air is to use Keeling plots (delta(13)C versus 1/CO2 concentration). This approach requires the precise determination of both CO2 concentration ([CO2]), usually measured with an infrared gas analyser (IRGA) in the field, and the analysis of delta(13)C by isotope ratio mass spectrometry (IRMS) in the laboratory. We measured [CO2] with an IRGA in the field (n = 637) and simultaneously collected air samples in 12 mL vials for analysis of the 13C values and the [CO2] using a continuous-flow isotope ratio mass spectrometer. In this study we tested if measurements by the IRGA and IRMS yielded the same results for [CO2], and also investigated the effects of different sample vial preparation methods on the [CO2] measurement and the thereby obtained Keeling plot results. Our results show that IRMS measurements of the [CO2] (during the isotope analysis) were lower than when the [CO2] was measured in the field with the IRGA. This is especially evident when the sample vials were not treated in the same way as the standard vials. From the three different vial preparation methods, the one using N2-filled and overpressurised vials resulted in the best agreement between the IRGA and IRMS [CO2] values. There was no effect on the (13)C-values from the different methods. The Keeling plot results confirmed that the overpressurised vials performed best. We conclude that in the cases where the ranges of [CO2] are large (>300 ppm; in our case it ranged between 70 and 1500 ppm) reliable estimation of the [CO2] with small samples using IRMS is possible for Keeling plot application. We also suggest some guidelines for sample handling in order to achieve proper results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

LC/MS stable isotope analysis of dissolved organic carbon in stream and soil waters

A commercial interface coupling liquid chromatography (LC) to a continuous-flow isotope ratio mass spectrometer (IRMS) was used to analyse δ 13 C of dissolved organic carbon (DOC) in natural waters. Stream and soil waters from a farmland plot in a hedgerow landscape were selected for application. Based on wet chemical oxidation of dissolved organics the LCIRMS interface allows on-line injection...

متن کامل

Liquid chromatography/mass spectrometry stable isotope analysis of dissolved organic carbon in stream and soil waters.

A commercial interface coupling liquid chromatography (LC) to a continuous-flow isotope ratio mass spectrometry (CF-IRMS) instrument was used to determine the δ(13) C of dissolved organic carbon (DOC) in natural waters. Stream and soil waters from a farmland plot in a hedgerow landscape were studied. Based on wet chemical oxidation of dissolved organics the LC/IRMS interface allows the on-line ...

متن کامل

Analysis of low-concentration gas samples with continuous-flow isotope ratio mass spectrometry: eliminating sources of contamination to achieve high precision.

Developments in continuous-flow isotope ratio mass spectrometry have made possible the rapid analysis of delta13C in CO2 of small-volume gas samples with precisions of < or = 0.1 per thousand. Prior research has validated the integrity of septum-capped vials for collection and short-term storage of gas samples. However, there has been little investigation into the sources of contamination durin...

متن کامل

Continuous-flow isotope ratio mass spectrometry method for carbon and hydrogen isotope measurements on atmospheric methane

We describe a continuous-flow isotope ratio mass spectrometry (CF-IRMS) technique for high-precision δD and δ13C measurements of atmospheric methane on 40 mL air samples. CH4 is separated from other air components by utilizing purely physical processes based on temperature, time and mechanical valve switching. Chemical agents are avoided. Trace amounts of interfering compounds can be separated ...

متن کامل

An automated sampler for collection of atmospheric trace gas samples for stable isotope analyses

Research focused on the isotopic composition of CO2 exchange between terrestrial ecosystems and the atmosphere has been historically constrained by the need for personnel to be present at remote field sites for sample collection. In practice, this has limited sampling frequency and duration, and potentially even biases sampling events to fair weather periods. We have developed an automated samp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Rapid communications in mass spectrometry : RCM

دوره 22 24  شماره 

صفحات  -

تاریخ انتشار 2008