Survey of permanent central venous catheters for haemodialysis in the UK.
نویسندگان
چکیده
BACKGROUND Venous catheter haemodialysis may be necessary in some patients without arterio venous fistulae on dialysis for end-stage renal failure. We conducted a survey to compare management of these catheters in different units in the UK. METHODS Postal questionnaires were sent to nurses in charge of 81 renal units in the UK for a twelve month study period in 1994 to find out the type of catheter used, catheter after insertion care, the rate and management of exit site infections, and bacteraemia. RESULTS (1) Total number of questionnaires returned 66 (81.5%). (2) 63.6% of renal units used double lumen Permcath catheters, 16.7% single lumen (Francis/Kimal, Gambro or Vascath), 10.6% use both double and single lumen catheters and 9.1% of renal units only use temporary polyurethane catheters. (3) Catheter exit site aseptic dressing technique was used in 84.8% of renal units, clean technique in 15.2%. 66.8% change dressings at each dialysis session, 22.7% weekly. The majority of renal units (63.6%) had one nurse to change the dressing, used Betadine as a cleaning agent and Mepore to cover the exit site. (4) 75.8% did not know the exact incidence of episodes of sepsis and/or exit site infections. Flucloxacillin was the antibiotic of choice for each catheter related sepsis episode. CONCLUSION During this study period most renal units used Permcaths as first choice for long term catheter dialysis, the after insertion care of which varied. The number of episodes of sepsis was unknown. We suggest UK collection of data for all long term catheters and related problems for audit purposes.
منابع مشابه
Survey of a Practical Approach to Central Venous Catheterization in Pediatric Patients
Background Central venous catheter (CVC) is used for measuring hemodynamic variables, transfusion of blood, fluids and medications when peripheral vascular lack sufficiency. Unfortunately CVC is associated with many complications ranging from anxiety and discomfort for the patient to severe mechanical side effects such as arterial lacerations, pleural and pericardial injury as well as infection...
متن کاملTesio catheters: findings in post-mortem examination.
Vascular access is still the 'Achilles heel' in the haemodialysis treatment. Access-related problems account for approximately 25% of hospitalizations in haemodialysis patients. In patients lacking a suitable vascular anatomy or presenting repeated a-v fistula thrombosis due to vascular problems and/or hypotension, a permanent central venous catheter can establish a reliable long-term vascular ...
متن کاملMethicillin-Resistant Staphylococcus aureus [Mrsa] Catheter Related Bloodstream Infections in Renal
Central venous catheters in nephrology were originally introduced to provide temporary vascular access for shortterm dialysis and were never meant to play a part in the dialysis patients’ long term care. Currently, tunneled, cuffed, doublelumen silastic catheters are used for permanent vascular access in many patients, particularly those with limited alternative options for vascular access and ...
متن کاملInterventional radiology in haemodialysis fistulae and grafts
Renal failure is treated by dialysis or renal transplantation. About 63% of patients are treated with haemodialysis, 9% with peritoneal dialysis and 28% with renal transplantation.1 Haemodialysis can be performed through central venous catheters (internal jugular, subclavian and femoral vein) or through a permanent arteriovenous access. Long-term patency of central catheters is low, because the...
متن کاملA Comparison effect of collaborative-based training program and lecture method on nurses’ performance of central venous catheter care
Background and Objectives: Improving nurses’ adherance with nursing standard catheter care is needed to enhance the quality of central venous catheters care. This study aimed to compare the effect of collaborative teaching method and lecture method on nursesing care of Central venous catheters. Materials and Methods: This quasi- experimental pretest-post test design study was conducted...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 11 5 شماره
صفحات -
تاریخ انتشار 1996