MYOCARDIAL ISCHEMIA Accuracy and Feasibility of Contrast Echocardiography for Detection of Perfusion Defects in Routine Practice Comparison With Wall Motion and Technetium-99m Sestamibi Single-Photon Emission Computed Tomography
نویسنده
چکیده
Objectives. We sought to assess the feasibility and accuracy of myocardial contrast echocardiography (MCE) using standard imaging approaches for the detection of perfusion defects in patients who had a myocardial infarction (MI). Background. Myocardial contrast echocardiography may be more versatile than perfusion scintigraphy for identifying the presence and extent of perfusion defects after MI. However, its reliability in routine practice is unclear. Methods. Fundamental or harmonic MCE was performed with continuous or triggered imaging in 203 patients with a previous MI using bolus doses of a perfluorocarbon-filled contrast agent (NC100100). All patients underwent single-photon emission computed tomography (SPECT) after the injection of technetium-99m (Tc-99m) sestamibi at rest. Quantitative and semiquantitative SPECT, wall motion and digitized echocardiographic data were interpreted independently. The accuracy of MCE was assessed for detection of segments and patients with moderate and severe sestamibi-SPECT defects, as well as for detection of patients with extensive perfusion defects (>12% of left ventricle). Results. In segments with diagnostic MCE, the segmental sensitivity ranged from 14% to 65%, and the specificity varied from 78% to 95%, depending on the dose of contrast agent. Using both segmentand patient-based analysis, the greatest accuracy and proportion of interpretable images were obtained using harmonic imaging in the triggered mode. For the detection of extensive defects, the sensitivity varied from 13% to 48%, with specificity from 63% to 100%. Harmonic imaging remained the most accurate approach. Time since MI and SPECT defect location and intensity were all determinants of the MCE response. The extent of defects on MCE was less than the extent of either abnormal wall motion or SPECT abnormalities. The combination of wall motion and MCE assessment gave the best balance of sensitivity (46% to 55%) and specificity (82% to 83%). Conclusions. Although MCE is specific, it has limited sensitivity for detection of moderate or severe perfusion defects, and it underestimates the extent of SPECT defects. The best results are obtained by integration with wall motion. More sophisticated methods of acquisition and interpretation are needed to enhance the feasibility of this technique in routine practice. (J Am Coll Cardiol 1998;32:1260–9) ©1998 by the American College of Cardiology
منابع مشابه
Comparison of post-exercise and post-vasodilator stress myocardial stunning as assessed by electrocardiogram-gated single-photon emission computed tomography.
BACKGROUND Exercise gated single-photon emission computed tomography (SPECT) using technetium-99m (99mTc)-sestamibi evaluates both myocardial perfusion during stress and wall motion >30 min after the stress, which has the potential to assess not only exercise-induced myocardial ischemia but also the development of myocardial stunning. METHODS AND RESULTS To evaluate the incidence of post-stre...
متن کاملComparison of myocardial contrast echocardiography with NC100100 and Tc sestamibi SPECT for detection of resting myocardial perfusion abnormalities in patients with previous myocardial infarction
Objective—To determine whether myocardial contrast echocardiography (MCE) following intravenous injection of perfluorocarbon microbubbles permits identification of resting myocardial perfusion abnormalities in patients who have had a previous myocardial infarction. Patients and interventions—22 patients (mean (SD) age 66 (11) years) underwent MCE after intravenous injection of NC100100, a novel...
متن کاملEvaluation by quantitative 99m-technetium MIBI SPECT and echocardiography of myocardial perfusion and wall motion abnormalities in patients with dobutamine-induced ST-segment elevation.
ST-segment elevation during exercise testing has been attributed to myocardial ischemia and wall motion abnormalities (WMA). However, the functional significance of ST-segment elevation during dobutamine stress testing (DST) has not been evaluated in patients referred for diagnostic evaluation of myocardial ischemia. DST (up to 40 micrograms/kg/min) with simultaneous echocardiography and techne...
متن کاملScintigraphic perfusion defects due to right ventricular apical pacing: a pitfall in clinical cardiology.
Right ventricular apical pacing (RVAP) with a left bundle branch block on the electrocardiogram may result in regional wall motion abnormalities and decreased left ventricular function (LVF). Furthermore, perfusion defects in dipyridamole technetium-99m-methoxisobutylisonitrile ((99m)Tc-MIBI) myocardial perfusion imaging may occur despite a normal coronary angiogram. In a 68 years old patient, ...
متن کاملEvaluation of coronary artery abnormalities in Williams syndrome patients using myocardial perfusion scintigraphy and CT angiography.
BACKGROUND Sudden death risk in Williams syndrome (WS) patients has been shown to be 25-100 times higher than in the general population. This study aims to detect coronary artery anomalies and myocardial perfusion defects in WS patients using noninvasive diagnostic methods. METHODS This study features 38 patients diagnosed with WS. In addition to physical examination, electrocardiography, and...