Real-time controller for foot-drop correction by using surface electromyography sensor.
نویسندگان
چکیده
Foot drop is a disease caused mainly by muscle paralysis, which incapacitates the nerves generating the impulses that control feet in a heel strike. The incapacity may stem from lesions that affect the brain, the spinal cord, or peripheral nerves. The foot becomes dorsiflexed, affecting normal walking. A design and analysis of a controller for such legs is the subject of this article. Surface electromyography electrodes are connected to the skin surface of the human muscle and work on the mechanics of human muscle contraction. The design uses real surface electromyography signals for estimation of the joint angles. Various-speed flexions and extensions of the leg were analyzed. The two phases of the design began with surface electromyography of real human leg electromyography signal, which was subsequently filtered, amplified, and normalized to the maximum amplitude. Parameters extracted from the surface electromyography signal were then used to train an artificial neural network for prediction of the joint angle. The artificial neural network design included various-speed identification of the electromyography signal and estimation of the angles of the knee and ankle joints by a recognition process that depended on the parameters of the real surface electromyography signal measured through real movements. The second phase used artificial neural network estimation of the control signal, for calculation of the electromyography signal to be stimulated for the leg muscle to move the ankle joint. Satisfactory simulation (MATLAB/Simulink version 2012a) and implementation results verified the design feasibility.
منابع مشابه
Detection of Fuel Adulteration in Real Time Using Optical Fiber Sensor and Peripheral Interface Controller
Detection of fuel adulteration in real time is the most important need of the world as it generates the hazardous effects on the environment, living and nonliving things. Various automotive users and fuel providers may mix kerosene in petrol and diesel. Adulterated fuel increases air pollution, as well as reduces the performance of vehicle engines. Such a malpractice in fuel is prevailing becau...
متن کاملTowards life-long learning of posture control for s-EMG prostheses
Surface electromyography (sEMG) sensors are a promising way to control upperlimb prostheses. However a training session is necessary in order to set up the controller that will make sEMG based movement possible. All data recorded during the training session are used by a machine learning algorithm to make a posture classification, that will allow the controller to distinguish each posture. T...
متن کاملBiofeedback Controlled Ankle Foot Orthosis for Stroke Rehabilitation to Improve Gait Symmetry
Stroke affects 700,000 Americans per year resulting in the largest cause of long-term disability in the United States. Dropfoot is a common condition associated with residual disabilities of stokes and is characterized as a paralysis or weakness of the dorsiflexor muscles of the foot and ankle. The result is an abnormal gait cycle caused by the dragging of the foot and toes during the swing pha...
متن کاملPeroneal nerve injury with foot drop complicating ankle sprain--a series of four cases with review of the literature.
Foot drop has many etiologies. One rarely mentioned and often neglected reason for foot drop is an acute inversion sprain of the ankle. Over the past 14 years, a collection of 32 cases of foot drop have been compiled in our orthopaedic and physiatric practices. All cases had appropriate evaluations, including electrodiagnostic studies (electromyography and nerve conduction studies) to determine...
متن کاملAdaptive Interference Reduction in Nerve Cuff Electrode Recordings
Neural signals (ENG) recorded from insulating cuffs fitted with electrodes and placed around nerve bundles may replace artificial sensors in providing feedback signals in functional electrical stimulation (FES) applications. Typical applications include correction of foot-drop, hand grasp in tetraplegic subjects and bladder voiding in certain types of incontinence. Unfortunately, the ENG signal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
دوره 227 4 شماره
صفحات -
تاریخ انتشار 2013