Equivalent circuit for the thermal analysis of cables in non-vented vertical risers
نویسندگان
چکیده
This study presents an alternative methodological approach for thermal rating of power cables installed in vertical risers covered by unvented circular protective guards. An analogue thermal-electrical circuit is proposed for the thermal analysis of cables inside vertical risers. The proposed equivalent analogue model is verified by means of indoor experiments and finite-element simulations with various cable and riser geometries for various load currents. Single cable and trefoil configurations are studied. Analysis performed on measured, simulated and calculated data establish the validity of the proposed model. Computations performed using the proposed method give results within 5% of measured conductor temperature. It is concluded that increasing riser height has minimal or insignificant impact on conductor temperature, whereas, reducing riser diameter, holding other variables constant increases conductor temperature and therefore reduces cable ampacity.
منابع مشابه
Closed-Form Solutions for Broad-Band Equivalent Circuit of Vertical Rod Buried in Lossy Grounds Subjected to Lightning Strokes
Abstract— In this paper, input impedance of a vertical rod under lightning stroke is first computed by applying the method of moments (MoM) on the Maxwell’s equations. The circuit model is then achieved through applying modified vector fitting (MVF) on the computed input impedance. After then the equivalent circuit is again extracted for a few values of soil conductivity and rod radius. Finally...
متن کاملImpact of Ocean-Land Mixed Propagation Path on Equivalent Circuit of Grounding Rods
In this paper, the effect of ocean-land mixed propagation path on the lightning performance of grounding rods is investigated. This effect is focused on two problems. The first is extracting exact equivalent circuit of grounding rods in the presence of oceans. The equivalent circuit can be used in transient analysis of power systems in the neighboring oceans. In the second one, this effect on t...
متن کاملEffect of Riser-Seabed Interaction on the Dynamic Behavior of Risers
In recent years, the production of oil and gas has been developed in deep water depths which exceed 500m. Deep water developments are being followed strongly in different parts of the world (Caspian Sea, Gulf of Mexico, etc.). The movement of floater causes severe stress at the touchdown point (TDP) in steel catenary risers (SCR). The main objective of this study was to simulate the exact behav...
متن کاملDamage Detection in Post-tensioned Slab Using 2D Wavelet Transforms
Earthquake force, loading more than structural capacity, cracking, material fatigue and the other unpredicted events were undeniable in the structure life cycle in order that environmental conditions of the structure would be changed and treats health. Damage of structures such as crack, corrosion of the post tension cables from inappropriate grouting of the post tension structures and etc. can...
متن کاملElectrical and Thermal Analysis of Single Conductor Power Cable Considering the Lead Sheath Effect Based on Finite Element Method
This paper investigates the effect of metallic sheaths on losses and temperature of medium voltage power cables. Two grounding methods of sheaths, including both ends bonding and single point bonding that causes different situations on cable ampacity, are considered. Electrical losses of cables that are main sources of heat are calculated in both conductor and metallic sheath of the cables. She...
متن کامل