Forty subjects, 20 women and 20 men, were exposed to airflows from five different directions: horizontally towards the front, the back, and the left side and vertically upwards and downwards. The subjects were exposed to stepwise increased air velocities ranging from less than 0.10 m/s to 0.40 m/s at three temperature levels 20, 23 and 26 o C. The results showed that airflow direction has an impact on perceived discomfort due to draught. At 20 o C and 23 o C, airflow from below was perceived as most uncomfortable followed by airflows towards the back and front. At 26 o C airflow from above and towards the back caused most dissatisfaction due to draught, but generally only a few of the subjects perceived discomfort at this temperature. Discomfort due to draught was most often felt at the body regions directly exposed to the airflow. These were the legs, the feet, and the lower back at airflow from below; the neck, the shoulders and the hands at airflow from above; the neck, the back, the shoulders and the legs at airflow from behind; the knee and the arm facing the windbox when exposed to air movements directed towards the side; and the hands and the knees when exposed to air movements towards the front.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Velocity and Direction of Airflow on Thermal Comfort and Energy Consumption: Case of New Exclusive Cooling Systems

The application of personalized ventilation systems, particularly in the buildings, is one of the new topics that today presented to it, because of their proper performance in reducing energy consumption and creating better thermal comfort conditions. In the current study, the energy consumption of a personalized cooling system installed in a room, considering the constraint of thermal comfort,...

متن کامل

Measurements and Modeling of Flue Height Influence on Air Pollution Emissions and Thermal Efficiency of Natural Draught Gas Fired Boilers

This paper presents and analyses results from experimental and CFD work undertaken on a 24 kW domestic natural-draught gas fired boiler. The effect of chimney height on boiler flue gases is being considered to address the need for increasing concern over environmental safety as well as saving of energy. A multi-component analysis computer (DELTA 2000 CD) is used to analyze the flue gases. 3D nu...

متن کامل

Draught and its economic consequences in rural area Case: Dodangeh district Behbahan

Introduction: Draught is being considered as a climatic reality in arid and semi-arid regions such as Iran. Drought is capable of generating drastic impacts over water and soil resources, vegetation, animals and human beings. Water is a prominent factor as far as agricultural product is concerned specially in arid zones. Draught and its impact on water resources will bear unpleasant conseque...

متن کامل

ارزیابی کارایی سیستم تهویه مطبوع یک ساختمان اداری در شهر تهران

Introduction: One of the factors influencing on indoor air quality of the buildings is performance of HVAC (heating, ventilation, and air conditioning) systems. These systems supply clean and odorless air, with temperature, humidity, and air velocity within comfort ranges for the residents. The aim of this study was to evaluate performance HVAC system in an administrative building in Tehran. .M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997