Compressed sensing with synchronized cardio-respiratory sparsity for free-breathing cine MRI: initial comparative study on patients with arrhythmias
نویسندگان
چکیده
Background Evaluation of myocardial function with MRI is challenging on patients with impaired breath-hold (BH) capabilities or arrhythmias due to the difficulty of respiratory motion suspension and synchronization of cardiac cycles. Compressed sensing (CS) enables free breathing (FB) real-time cine imaging with improved spatiotemporal resolution, but conventional temporal sparsifying transforms do not account for respiratory motion, which limits its performance. In this work, we propose to acquire data continuously in FB using a golden-angle radial sampling scheme and reconstruct images with separated but synchronized cardiac and respiratory motion dimensions using self-detected motion signals. For patients with arrhythmias, both “normal” and “ectopic” cycles are reconstructed by sorting out cardiac cycles with different lengths. The performance of the proposed method was compared to Cartesian BH approach using retrospective ECG-gating in 9 patients.
منابع مشابه
Assessment of Left Ventricular Function and Mass on Free-Breathing Compressed Sensing Real-Time Cine Imaging.
BACKGROUND Compressed sensing (CS) cine magnetic resonance imaging (MRI) has the advantage of being inherently insensitive to respiratory motion. This study compared the accuracy of free-breathing (FB) CS and breath-hold (BH) standard cine MRI for left ventricular (LV) volume assessment.Methods and Results:Sixty-three patients underwent cine MRI with both techniques. Both types of images were a...
متن کاملHighly-Accelerated Real-Time Cine MRI using compressed sensing and parallel imaging
Introduction Breath-hold cine MRI with balanced steady-steady free precession (b-SSFP) may yield non diagnostic image quality in patients with impaired breath-hold capacity and/or arrhythmias. In such patients, it may be necessary to perform real-time cine MRI. Currently, dynamic parallel imaging methods, such as TSENSE [1] and TGRAPPA [2], can be used to achieve only moderate acceleration rate...
متن کاملRespiratory Motion Correction for Compressively Sampled Free Breathing Cardiac MRI Using Smooth l1-Norm Approximation
Transformed domain sparsity of Magnetic Resonance Imaging (MRI) has recently been used to reduce the acquisition time in conjunction with compressed sensing (CS) theory. Respiratory motion during MR scan results in strong blurring and ghosting artifacts in recovered MR images. To improve the quality of the recovered images, motion needs to be estimated and corrected. In this article, a two-step...
متن کاملMotion corrected compressed sensing for free-breathing dynamic cardiac MRI.
Compressed sensing (CS) has been demonstrated to accelerate MRI acquisitions by reconstructing sparse images of good quality from highly undersampled data. Motion during MR scans can cause inconsistencies in k-space data, resulting in strong motion artifacts in the reconstructed images. For CS to be useful in these applications, motion correction techniques need to be combined with the undersam...
متن کاملA frame work for non-rigid motion corrected compressed sensing for highly accelerated MRI
Introduction: Compressed Sensing (CS) has been demonstrated to reconstruct sparse MR images of adequate quality from highly undersampled data [1], resulting in reduced scan times. In MRI, extensive motion during the acquisition (e.g. respiratory motion in cardiac scans) can cause inconsistencies in the k-space data, introducing blurring and ghosting like motion artefacts in the reconstructed im...