Variability in the establishment of an external reference point for central venous pressure measurement in children.

نویسندگان

  • Aline S C Belela
  • Mavilde L G Pedreira
  • Maria Angélica S Peterlini
  • Denise M Kusahara
  • Werther B Carvalho
  • Gisele C Gentil
چکیده

OBJECTIVE To investigate the variability in the establishment of the midaxillary line as external reference point (ERP), by different healthcare workers, for the measurement of central venous pressure in children. METHODS Descriptive and correlational study carried out in a pediatric intensive care unit of a teaching hospital. During the establishment of the midaxillary line as ERP for central venous pressure measurement, five assessments of the same patient made by healthcare workers and one assessment made by a trained evaluator were compared. A total of 120 assessments were made by 44 healthcare workers, 17 (38.6%) by nursing assistants and nursing technicians, 16 (36.3%) by nurses and 11 (25.1%) by physicians, in addition to 24 assessments made by the trained evaluator. The data were analyzed using the chi-square test, ANOVA, Kruskal-Wallis test and t test. Significance level was set at 5%. RESULTS There was statistically significant difference between the assessments made by healthcare workers and by the evaluator (p < 0.001). The comparison of the variability in the measurements made by healthcare workers revealed that 56 (46.7%) measurements were lower than those obtained by the evaluator (range from -0.5 to -9), 44 (36.7%) were higher (range from 0.5 to 4) and 20 (16.7%) were concordant (zero variability). Professional category did not influence the concordance between the ERPs (p = 0.899), or the variability observed (p = 0.778). However, the measurements made by professionals with greater experience in intensive care tended to differ more sharply from those made by the evaluators. CONCLUSION The indications of the midaxillary line as ERP presented variations when measured by the healthcare team and by the trained evaluator. Variability was not influenced by professional category, and the more experienced the healthcare worker, the greater the probability for underestimation of the ERP. According to the results of this study, such situations may compromise both the efficacy of this procedure and patient safety.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Central Venous Pressure from Intraocular Pressure

Background: In many clinical situations, knowledge of central venous pressure (CVP) is important.  Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery.  Those with carotid artery or jugular venous diseases as we...

متن کامل

بررسی تأثیر استفاده از چک لیست ثبت اقدامات بر عملکرد پرستاران بخش مراقبت های ویژه در اندازه‌گیری فشار ورید مرکزی

  Background & Aim: The central venous pressure measurement is a common and important care provided by nurses in intensive units. The measurement should be according to the pre-defined standards. The purpose of this study was to evaluate the effect of using a checklist in measuring central venous pressure by nurses .   Methods & Materials: This was a nonequivalent group design on 70 nurses w...

متن کامل

Correlation of Ultrasonographic Measurement of Inferior Vena Cava Collapsibility Index with Central Venous Pressure in Diagnosis and Management of Neonatal Shock

Background: Neonatal intensive care unit (NICU)Conventionally, Central Venous Pressure (CVP) monitoring has beenused by intensivists to measure intravascular volume. However, it is an invasive procedure resulting in many complications. Non-invasive ultrasonographic measurement of inferior vena cava collapsibility index (IVC-CI) is a promising alternative. Therefore, this study wasconducte...

متن کامل

بررسی ارزش تشخیصی میزانCaval index در تعیین فشار ورید مرکزی پایین در مقایسه با روش تهاجمی در بیماران بستری در ICU بیمارستان شهید باهنر کرمان

Introduction: Measurement of central venous pressure can be regarded as a beneficial guide in order to assess a patient's hemodynamic status, specifically in patient with sever sepsis and septic shock, for whom a central venous pressure of less than 8mmhg is considered as an indicator for aggressive intravenous fluid replacement. Therefore, this study aimed to investigate the ultrasonographic e...

متن کامل

Comparing the anatomy of the intrathoracic systemic central venous system in Iranian pediatrics and adults based on chest CT scan and evaluation of rate of catheter malposition in children

Background: Central venous catheterization is a procedure that is being performed frequently especially in critical clinical settings. In such conditions, good knowledge of the surface anatomy of venous structures is vital to avoid possible complications which could result in life-threatening situations such as bleeding and pneumothorax. Considering the difference between venous anatomy of chil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Jornal de pediatria

دوره 82 5  شماره 

صفحات  -

تاریخ انتشار 2006